I. Prologue
Thanks for using our products. Please read this manual carefully before installation and
operation. There are information for installation,operation,maintenance,commissioning.
Rigorous design and production standard make sure floor heating water unit running
safely and efficiently as well as excellent reliability and adaptability.
We will not responsible for any loss caused by any nonstandard operation.
The machine should be installed by qualified professional personnel and must be
connected according to the circuit diagram of the machine. The following items should be
focused:
1. Before installation, please confirm if your local voltage is match with the voltage showed on
the machine’s nameplate and if the carrying capacity of the power supply, wires and
sockets are suitable for this machine’s input power;
2. Users are not allowed to change the power cord or socket. Wiring work must be carried out
by a qualified electrician and ensure that the metal part of the machine has a good
grounding, ensure the grounding resistance ≤10Ω. Changing the ground mode is strictly
forbidden;
3. After the completion of the construction of all wiring work, please make sure to recheck
everything before power on;
4. Do not Install the machine in the place which may have leakage of combustible gas;
5. Do not put your hands or foreign objects into the air outlet and fan of the unit. Otherwise, it
will be dangerous to the people and equipment;
6. In order to obtain a better energy-saving effect, the unit should be installed in
well-ventilated places;
7. Water used for this machine must be accordance with the GB standard of living water,
otherwise, if the machine is damaged, we will not take any responsibility.
ATTENTIONS:
1. Please make sure the water systems filled with water before the machine start working and
the drain valve should close.
(
The top of floor heating must be installed automatic exhaust
valve)
2. When the machine is operating, all the valves of the water systems must be in the open
position.
3. Unit’s water inlet line must be installed detachable type filter, according to the local water
cycle of floor heating pipe adding preservatives and antifreeze;
4. The maintenance of the machine must be carried out by the professional personnel.