NX-1700E Card Reader 

Scan:  To 
“present” or 
pass a card or 
FOB within 
sensing range 
of the card 
reader module. 

IV. ADDRESSING 

Once the reader is wired into the system, the module needs to be addressed. Unlike most 
NetworX expanders, the address of any particular reader is determined by itself after installation 
is complete.  Follow the procedures outlined under the section “PROGRAMMING”. When 
prompted to enter the module device number, a card must be scanned at the reader to initiate 
addressing (one short beep). When completed (1-2 seconds), the reader will beep back its 
address (long beeps).  Refer to Table IV-1 that follows for possible addresses. 
 

Table IV-1 

Beeps 

Address 

Beeps 

Address 

1 113 9 121 
2 114 10 122 
3 115 11 123 
4 116 12 124 
5 117 13 125 
6 118 14 126 
7 119 15 127 
8 120   

 

 
 

V. PROGRAMMING 

A. USING THE LED KEYPAD 

 

ACTION 

RESULT 

E

NTERING THE 

P

ROGRAM 

M

ODE

 

 

 

 

 

 

 

 

 

 

 

   Enters the Program Mode.  

Stay,  Chime,  Exit,  Bypass & Cancel LEDS will 
flash. 

 

[

Go To Program Code

Factory Default is 

 

 

 

 

 

 

 

 

   If the "Go To Program Code" is valid, the "Service" 

LED will flash and the 5 function LEDs will 
illuminate steady. You are now in the Program 
Mode and ready to select the module address. 

E

NTERING THE 

M

ODULE 

A

DDRESS

 

Scan a card. 

 

 

 

 

 

 

 

   The card reader will address itself.  

 

 

 # 

(example only) 

 

 

 

 

 

 

 

   Enters the module address.  Refer to Table IV-1 on 

page 5 for the address assigned by the card reader 
module itself. 

The Armed LED will illuminate while it is waiting for 
a programming location to be entered. 

Summary of Contents for NX-1700E

Page 1: ...NX1700EIE03 Supercedes NX1700EID03 NetworX Series NX 1700E Proximity Card Reader Installation and Startup...

Page 2: ...GE Interlogix Please refer to the current GE Interlogix product catalog for detailed warranty information Main 800 727 2339 Technical Support 800 727 2339 Outside the US 903 845 6941 Tech Support Fax...

Page 3: ...er Partition 11 Location 243 Programming the Zones 12 Location 244 Programming the Various Reader Timers 12 Location 245 Resetting the Reader Address 13 Location 246 Programming the Access Options 13...

Page 4: ...E EGRESS This is an optional EGRESS exit input To use this feature connect the normally open egress switch between this terminal and COM If this feature is not used there is no need to connect this wi...

Page 5: ...possible addresses Table IV 1 Beeps Address Beeps Address 1 113 9 121 2 114 10 122 3 115 11 123 4 116 12 124 5 117 13 125 6 118 14 126 7 119 15 127 8 120 V PROGRAMMING A USING THE LED KEYPAD ACTION R...

Page 6: ...is saved The new data is saved The keypad will increment and display the next segment s data NOTE Repeat these steps until the last segment is reached To Exit a Location Exits from this location The R...

Page 7: ...t is recommended that only one reader on the system be enabled to modify user cards and that this reader be located near a keypad This reader will transfer information to all other readers in the syst...

Page 8: ...ion ADDING MULTIPLE USERS WITH AUTO INCREMENT ACTION RESULT CANCEL Accesses Activation mode 3 digit user number Example if 4 digit user code or if 6 digit user codes If a valid user number is entered...

Page 9: ...readers will begin to flash Scan any card The card information for the user entered in the previous step will be cleared and LED1 will stop flashing After about 30 seconds all the readers in the syst...

Page 10: ...rol panel LED7 On to broadcast an X 10 function see Location 241 for programming LED8 On to send a Request To Exit RTE and activate the onboard open collector output Default is On Location 243 Segment...

Page 11: ...e same as for Single Beep Scan Function This location only needs to be programmed if Location 0 Segment 3 Option 7 is set Use the above table Default is 2 LOCATION 242 PROGRAMMING THE OPTIONS AND READ...

Page 12: ...as a door for access control This location must be programmed with a valid zone for monitored access control functions to work properly Default is 0 Additionally this zone must be configured in the c...

Page 13: ...address then it will sound an error beep LOCATION 246 PROGRAMMING THE ACCESS OPTIONS 2 segments of binary data Segment 1 Door Options LED1 On if locking mechanism is a Maglock or Drop Bolt LED2 On if...

Page 14: ...e for specific instructions Location 250 Opening Time for Schedule 2 Location 262 Opening Time for Schedule 6 Location 251 Closing Time for Schedule 2 Location 263 Closing Time for Schedule 6 Location...

Page 15: ...er Cards 9 16 Segment 10 User Cards 73 80 Segment 3 User Cards 17 24 Segment 11 User Cards 81 88 Segment 4 User Cards 25 32 Segment 12 User Cards 89 96 Segment 5 User Cards 33 40 Segment 13 User Cards...

Page 16: ...on to the control panel 5 On to send Auxiliary Function 1 to the control panel 6 On to send Auxiliary Function 2 to the control panel 7 On to broadcast an X 10 function Loc 241 for programming 8 On to...

Page 17: ...uzzer follows keypad buzzing 4 On if ding dong chime enabled Opt 3 chime must be enabled 5 On if an RTE from a scanned card is to be logged as Code Entry 6 On if reader is in NX 1700E Legacy Mode 7 On...

Page 18: ...00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000...

Page 19: ...s active on Wednesday 5 On if schedule is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is active on Saturday 8 On if schedule is disabled on holidays 253 14 OPENING TIME FO...

Page 20: ...s active on Wednesday 5 On if schedule is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is active on Saturday 8 On if schedule is disabled on holidays 262 14 OPENING TIME FO...

Page 21: ...holidays 271 14 HOLIDAYS IN JANUARY 8 max No holidays _ _ _ _ _ _ _ _ 272 14 HOLIDAYS IN FEBRUARY 8 max No holidays _ _ _ _ _ _ _ _ 273 14 HOLIDAYS IN MARCH 8 max No holidays _ _ _ _ _ _ _ _ 274 14 HO...

Page 22: ...1192E 192 Zone LCD Keypad NX 848E KIT NX 8E Control NX 148E LED Keypad 40VA Transformer NX 216E 16 Zone Expander Module NX 8 8 48 Zone Control Only NX 320E Smart Power Supply and Buss Extender NX 848...

Page 23: ...egacy mode Request To Exit RTE A zone can be programmed to monitor an open door The RTE activates the onboard open collector output and sends a message on the buss Scan To present or pass a card or FO...

Page 24: ...A Standby with Green LED 110mA Maximum OPERATING TEMPERATURE 31 to 151 degrees F 35 to 66 degrees C SHIPPING WEIGHT 1 lb 1420 N MAIN STREET GLADEWATER TEXAS 75647 Main 800 727 2339 Technical Support 8...

Reviews: