NX-1700E Card Reader
10
VII. PROGRAMMING
LOCATIONS
SCAN METHODS: Legacy mode is default. Alternative mode is shown below in brackets { }.
Refer to Location 242 Segment 1 on page 11, and the Glossary on page 23 for explanation.
L
OCATION
0 P
ROGRAMMING THE
S
CAN
F
UNCTIONS
(3 segments of binary data) Location 0 is used to select the particular function(s) that are activated when a card is
scanned. More than one function may be selected. If more than one function is selected, they will execute in order from
function 1 to function 8.
Functions 1-6 will be performed based on the user’s authority as programmed by the [
] [6] function
(refer to keypad user manual).
Segment 1
Single Scan Function {Single Beep}
Program the functions that are performed when a card is scanned {one beep}.
LED1 -
"On" to send Code Entry function to the control panel.
LED2 -
"On" to activate the Armed Away mode.
LED3 -
"On" to activate the Armed Stay mode.
LED4 -
"On" to send the Disarm function to the control panel.
LED5 -
"On" to send Auxiliary Function #1 to the control panel.
LED6 -
"On" to send Auxiliary Function #2 to the control panel.
LED7 -
"On" to broadcast an X-10 function (see Location 241 for programming).
LED8 -
"On" to send a Request To Exit (RTE); and activate the onboard open collector output.
(Default is “On”)
Location 243, Segment 2 must be programmed with a valid zone number
for the RTE to be sent.
Segment 2
Double Scan Function {Double Beep}
Program the functions that are performed when a card is scanned twice within the 2 Scan Hold Time {two beeps}.
Location 244, Segment 1 programs the length of time between beeps. The descriptions of the options are the same as
for Single Beep Scan Function. Default is 1.
Segment 3
Single Scan Hold Function {Triple Beep}
Program the functions that are performed when a card is scanned and held at the reader for the duration of the 2 Scan
Hold Time {three beeps}. Location 244, Segment 1 programs the length of time between beeps. The descriptions of the
options are the same as for Single Beep Scan Function. Default is 1.
L
OCATIONS
1 - 240 R
ESERVED
L
OCATION
241 P
ROGRAMMING THE
X-10 A
DDRESS FOR THE
S
CAN
F
UNCTIONS
(5 segments of numerical data)
Segment 1
Program a number from 0 -15 to represent the corresponding X-10 Module Number from the following table.
Default is 0.
Module 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Seg 1
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15