NX-1700E Card Reader
12
Segment 2
LED1 (Green) Options:
LED1 - "On" to follow Ready status of system. (Default is “On”)
LED2 - "On" to toggle with the open collector output activation. (Default is “On”)
LED3 - "On" if inverted.
LED4 - Reserved.
LED5 - Reserved.
LED6 - Reserved.
LED7 - Reserved.
LED8 - Reserved.
Segment 3
LED2 (Red) Options:
LED1 - "On" to follow Armed status of system. (Default is “On”)
LED2 - "On" to toggle with the open collector output activation.
LED3 - "On" if inverted.
LED4 - Reserved.
LED5 - Reserved.
LED6 - Reserved.
LED7 - Reserved.
LED8 - Reserved.
Segment 4
Reader Partition:
LED1 - "On" if reader is in Partition 1. (Default is “On”)
LED2 - "On" if reader is in Partition 2. (Default is “On”)
LED3 - "On" if reader is in Partition 3. (Default is “On”)
LED4 - "On" if reader is in Partition 4. (Default is “On”)
LED5 - "On" if reader is in Partition 5. (Default is “On”)
LED6 - "On" if reader is in Partition 6. (Default is “On”)
LED7 - "On" if reader is in Partition 7. (Default is “On”)
LED8 - "On" if reader is in Partition 8. (Default is “On”)
L
OCATION
243 P
ROGRAMMING THE
Z
ONES
(2 segments of numerical data)
Segment 1
Door Shunt Zone
Program the zone that will be monitored as a door for access control. This location must be programmed with a valid
zone for monitored access control functions to work properly. (Default is 0)
Additionally, this zone must be configured in the control panel as a Door Shunt zone by programming an
unused Zone Type Characteristic in locations 111-169 (Seg 4, Opt 4).
Segment 2
Request To Exit (RTE) Zone
Program the zone that will be monitored to signal an RTE. If this segment is programmed with a valid zone and the
zone is faulted, the reader will activate its onboard open collector output and send the RTE. (Default is 0)
Additionally, this zone must be configured in the control panel as an RTE zone by programming an unused
Zone Type Characteristic in locations 111-169 (Seg 4, Opt 3).
L
OCATION
244 P
ROGRAMMING THE
V
ARIOUS
R
EADER
T
IMERS
(4 segment of numerical data)
Segment 1
Scan Time
Enter the amount of time required to hold a card between beeps to activate the functions programmed in Location 0,
Segments 2 and 3. This timer is timed in 1/100-second increments from 0 to 2.55 seconds. (Default is 100 = 1 second).
Segment 2
Relay Active Time
Enter the amount of time the onboard open collector output is energized once activated. This timer is timed in 1-second
increments from 0 to 255 seconds. (Default is 10 = 10 seconds).