INTERCONNECTION CABLE WIRING METHOD
The cable connecting the terminals and devices to the SERIMUX must be terminated with RJ45 connectors and must be wired
according to the EIA/TIA 568 B industry standard. Wiring is as per the table and drawing below.
Pin
Wire Color
Pair
Function
1
White/Orange
2
T
2
Orange
2
R
3
White/Green
3
T
4
Blue 1
R
5
White/Blue
1
T
6
Green 3
R
7
White/Brown
4
T
8
Brown 4
R
Figure 61- View looking into RJ45 female
TROUBLESHOOTING
If the Console Switch is not working properly, consider the suggestions below to see if a solution can be found.
Problem
Cause
Solution
No Front Panel LEDs are illuminated
No power to SERIMUX
Check all power connections
SERIMUX is not working properly
•
Poor
Connections
•
Port not configured correctly
•
Ports not initialized
•
Verify that all cables are securely
connected
•
Verify that the port configuration
matches that of the device connected
•
Power-up the CPUs first, then the
SERIMUX
Cannot Connect to port/device
•
Port settings not correct
•
Wrong cable adapter used
•
Connections are loose
•
Verify proper communication settings
(pg 8)
•
Verify that adapter is one specified in
Appendix C.
•
Verify that all cable connections are
secure
Commands entered from front panel
keypad are not accepted
Buttons are being pressed too rapidly
1) Make sure the Keypad PIN is
entered properly.
2) Press the “Enter” key before typing
the PIN to discard the previous
entry.
3) Try the PIN again but slow down
the button sequence- approx 1/2
sec between each press.
SERIMUX will not accept username
or password
Usernames and passwords are case
sensitive
Verify characters used and enter again.
Cannot access user menu on a port
Port is configured as host port
Configure port as user port. (pg. 10)
I cannot access the View Port Data
Buffer
Only the ROOT user can access this (see
page 14)
Login as the ROOT user
If the passwords or other important parameters are not available, the SERIMUX Console Switch can be re-initialized to the default
settings (see "Initialize SERIMUX Console Switch to default settings" on page 34).
Caution: During initialization, the customer modified parameter values will be replaced with the factory
default values; all ports will be placed in buffer mode; all passwords will be erased.
If the suggestions above have been tried and the NTI Console Switch is still not functioning properly, a solution to the problem
may be found on our website at http://www.networktechinc.com in our FAQ (Frequently Asked Questions) section, or, please call
us directly at
(800) 742-8324
(800-RGB-TECH)
in the US & Canada or
(330) 562-7070
(Worldwide)
and we’ll be happy to assist
in any way we can.