background image

Audio input:   

Audio input to the DVRi Peli is either via the line in RCA sockets (e.g. from a diver comms system) 
or via a standard microphone (see typical image below) plugged into the ¼” (6.35mm) mono jack 
socket. 

 

 
Frequency response: 80Hz – 12kHz 
Impedance: 600 

 

Sensitivity: -76dB @ 1kHz 
¼“ (6.35mm) plug 

 

 

 

Please ensure that no cables etc have been left on the surface of the DVRi Peli before closing the 
lid, as this could damage the monitor. 
 

2.3 

Installation of Inspector with removable drive 

 

1.  Install the DVRi in a 19” rack giving consideration to the height at which the unit is mounted 

to facilitate the easy removal of the hard drive. 

Note1

:  It is essential that sufficient space be allowed behind the recorder to allow the 

power supply-cooling fan to function correctly. 

Note2: 

If networking the DVRi, all network connections must be made and the network be 

live

 before switching on the DVRi, otherwise no streaming video will be available. 

 

NETmc Marine DVRi Manual rev. 5.3 May 2010   

6 of 43

 

 

Summary of Contents for DVR Inspector

Page 1: ...USER GUIDE FOR NETmc MARINE DVR Systems DVR Inspector DVRi Peli Rev 5 3 Firmware 4 3 22 May 2010...

Page 2: ...Using Windows Media Player 19 3 7 2 Using the NETmc Player 19 4 FAQs 22 5 How to contact NETmc Marine Support 23 Appendix i Technical Specifications 25 Appendix ii Definitions Abbreviations 26 Appendi...

Page 3: ...olution monitor keyboard and mouse DVRi Peli units are ideal for diver or mini ROV operations NETmc Marine s range of equipment also includes a variant of the DVR Inspector designed to accept an HD SD...

Page 4: ...ion for the recorder to function it is good practice but not essential to switch the internal power supply off when the recorder is not in use NOTE The DVR Inspector is designed to function with the c...

Page 5: ...indicators and so under normal circumstances the operator need not concern themselves with them Some newer models also have microphone headphone sockets on the front of the unit 2 2 DVRi Peli Hardware...

Page 6: ...d as this could damage the monitor 2 3 Installation of Inspector with removable drive 1 Install the DVRi in a 19 rack giving consideration to the height at which the unit is mounted to facilitate the...

Page 7: ...ough the drives are Hot Swappable we advise that drives are only inserted or removed when unit is powered OFF 6 Press the power on button on the front panel The two LEDs on the front of the removable...

Page 8: ...ally upon system boot If for any reason this does not happen or if the software has been closed down by a previous user the application can be launched by double clicking the NETmc DVR Inspector icon...

Page 9: ...the display goes through the following stages As soon as the unit is fully functioning the 2nd line of the display shows ENC and digits that are incrementing NOTE This is a useful indicator if you any...

Page 10: ...g and overlay manager In windows time settings the time zone should always be set to GMT Greenwich Mean Time Dublin Edinburgh Lisbon London with daylight saving disabled Then simply adjust the date cl...

Page 11: ...Recording Take Snapshot Still image grab Enter Setup Video Window Black Box Recording ON OFF Recording status indicator Take Live Video Clips Audio Indicator Start Recording Drive Capacity Note that t...

Page 12: ...green tick in the status bar is also necessary for Black Box recording This indicates that the housekeeping system is functioning whereby old files are deleted to make way for new ones enabling conti...

Page 13: ...E Units with SDI input have a different set up page see Appendix xi The set up settings of the DVRi can be changed however the unit will have been shipped from the factory configured with the optimal...

Page 14: ...e Composite input Y C This option is no longer available PAL Click here if input video is in the European format PAL NTSC Click here if input video is in the American Asian format Quality This sectio...

Page 15: ...e session number to zero in the example shown the session number is currently 134 Clip Path Select the location where video clips will be stored The default location is D Clips Clip Path Prefix Add a...

Page 16: ...on or off of the Black Box recording or if the Reqr for Stop Only box is ticked to prevent accidental switching off only Options at bottom of Set up Page Apply applies the changes Reset Undoes any ch...

Page 17: ...rt the recording simply click on the RECORD button When recording has started the status indicator changes to REC instead of IDLE the REC button will become depressed and the minute counter will start...

Page 18: ...RECORD button again The system will automatically create a new file automatically named as per the configuration in the SETUP page Similarly live video clips can be taken at any point during the recor...

Page 19: ...e_downloads htm Elecard is our preferred codec for viewing MPEG2 files A symptom that a codec is required is a black screen with audio but no picture If the video was recorded to a removable drive you...

Page 20: ...use the player controls near the bottom will open an explorer style dialog box from which you can select a file to be played To select the video file you want highlight it and then clicking OPEN Anoth...

Page 21: ...s shows the time of your mark out point If you save the file as a PKT then to play it back on a Windows Media Player you need to change the extension from pkt to mpg otherwise it will not play If you...

Page 22: ...ge lik se the camera is not outputting a signal and the ou not selected MPEG2 on a box th A Check that screen has reduced in size when I go to Windows and back dows de Q The viewing rived problem Shut...

Page 23: ...de In order to help our engineers solve the problem as quickly as possible please have ready the llowing information any information on events that happened prior to the fault that Not made to ensure...

Page 24: ...Section 6 APPENDICES NETmc Marine DVRi Manual rev 5 3 May 2010 24 of 43...

Page 25: ...ndom 10 300 Hz 0 004g2 Hz Non operating Vibration Low frequency 5 20 Hz 0 195 inches double amplitude High frequency 10 300Hz 5 0G 0 to peak Dimensions 482 W x 88 5 H x 455 D 2U case Weight 11kg Video...

Page 26: ...tandards Committee American Asian video format JPEG Joint Photographic Experts Group Mega bits per seconds Quality Control rsal Serial Bu tore path Local on hard disk where the video will be placed om...

Page 27: ...Appendix iii Keyboard short cut ShortCut Key Function Record R S Stop ebar Snap Spac NETmc Marine DVRi Manual rev 5 3 May 2010 27 of 43...

Page 28: ...e There are two parts to configuring the inte detect the encoder Secondly you must define where routine and anomalous vide display the clips an images are to be stored and which applications are to be...

Page 29: ...ck Tools Digital Video Setup from the Site module menu Enter data as follows 3 Digital Video Encoder Select Mnet from the drop down list dress of the digital video encode IP Address Enter the IP ad Di...

Page 30: ...Setup Firstly go to Baseline Basics Directories and set DV A DV G and DV R as shown below NB 192 168 1 xx should be replaced with the IP address of the DVRi NETmc Marine DVRi Manual rev 5 3 May 2010 3...

Page 31: ...Overlay Setup NB If Coabis fails to connect to the overlay try changing the Port NETmc Marine DVRi Manual rev 5 3 May 2010 31 of 43...

Page 32: ...grabs You then configure the Coabis PC to direct video and grabs to network_storage_IP coabis with the appropriate subfolder e g if the IP of the NAS box or server is 192 168 1 1 you would enter into...

Page 33: ...ecessary to change the mediaNET despatcher settings on the DVRi O From the Administrative Tools sectio m NET despatc Right click on the mediaNET despatcher line and select Properties From the tabs sel...

Page 34: ...e Use of Robocopy You should download or be supplied a copy of Robocopy by our integrator Copy it to a directory on the DVRi e g c robocopy Create a cmd file and configure it to run in the startup fol...

Page 35: ...Appendix viii Example Coabis interfacing diagrams NETmc Marine DVRi Manual rev 5 3 May 2010 35 of 43...

Page 36: ...NETmc Marine DVRi Manual rev 5 3 May 2010 36 of 43...

Page 37: ...NETmc Marine DVRi Manual rev 5 3 May 2010 37 of 43...

Page 38: ...ections Whichever data input system is used in order to enable overlay the input video signal should be first routed to Overlay In and then from Overlay Out to the regular video input to the DVRi usin...

Page 39: ...cally this will be a cable to a Coabis Scope or E Inspect workstation on Serial 1 while Serial 2 might be reserved for CP or other information The cable used should be a 9way fe m cable The wiring is...

Page 40: ...and the chosen serial ith the system but a null modem Up to 4 pages of text screen number Pages can also be saved and opened allowing for preset client specif configurations Overlay manager requires...

Page 41: ...eriments with different input rlay it is necessary to POWER CYCLE the whole DVRi i e the user will eed to switch the DVR off wait a few seconds and then switch it on again A Windows reboot will not wo...

Page 42: ...ed at a time DI units have a SDI pass through connector which can be used to pass the input video to a high solution monitor etc S re SDI units also have a different setup page see the screen grab bel...

Page 43: ...ncy energy and if not installed and used in with the instruction manual may cause harmful interference to radio communications peration of this equipment in a residential area is likely to cause harmf...