The DCPM module must be replaced in the chassis within five minutes of removal or the
associated controller will shut down.
4. Press the orange locking button on the module handle, and then slide the DCPM module out of the
chassis.
DCPM module orange locking button
5. Align the end of the DCPM module with the chassis opening, and then gently slide it into the chassis until it
clicks into place.
The module and slot are keyed. Do not force the module into the opening. If the module
does not go in easily, realign the module and slide it into the chassis.
The DCPM module LED lights when the module is fully seated into the chassis.
Dispose of batteries
You must dispose of batteries according to the local regulations regarding battery recycling or disposal. If you
cannot properly dispose of batteries, you must return the batteries to NetApp, as described in the RMA
instructions that are shipped with the kit.
https://library.netapp.com/ecm/ecm_download_file/ECMP12475945
Return the failed part to NetApp
After you replace the part, you can return the failed part to NetApp, as described in the RMA instructions
shipped with the kit. Contact technical support at
, 888-463-8277 (North America), 00-800-44-
638277 (Europe), or +800-800-80-800 (Asia/Pacific) if you need the RMA number or additional help with the
644