User Guide
T1/E1 configuration guide
48
Configuration is not saved. You must save the changed configurations
Command successfully end.
You Must RESET to apply modified value(s) to system.
MAX:/CONFIG/DTRUNK>
change cfg locode b8zs
Configuration is not saved. You must save the changed configurations
Command successfully end.
You Must RESET to apply modified value(s) to system.
MAX:/CONFIG/DTRUNK>
change cfg frame esf
Configuration is not saved. You must save the changed configurations
Command successfully end.
You Must RESET to apply modified value(s) to system.
MAX:/CONFIG/DTRUNK>
show cfg
==========================================================================
Digital Trunk Configurations
==========================================================================
trunk type (type) : T1
line code (lcode) : B8ZS(T1)
frame mode (frame) : ESF(T1)
signaling type (sig) : ISDN(CCS)
Voice Output Gain (vgain) : -3 dbm
PCM Input Gain (igain) : -3 dbm
==========================================================================
MAX:/CONFIG/DTRUNK>
MAX:/CONFIG/DTRUNK>
show line
==========================================================================
Channel Type configurations
==========================================================================
channel type | I=Incoming O=Outgoing B=Bothway
| S=Signaling-CH F=Frame-Sync X=undefined
--------------------------------------------------------------------------
channel number | 1 2 3
| 01234567890123456789012345678901
--------------------------------------------------------------------------
[slot/port] [3/0] | BBBBBBBBBBBBBBBBBBBBBBB
S
XXXXXXXX
In T1 PRI, B8ZS is usually used as line code
and frame mode as ESF.