User Guide
T1/E1 configuration guide
46
Configuration is not saved. You must save the changed configurations
Command successfully end.
You Must RESET to apply modified value(s) to system.
MAX:/CONFIG/R2>
show
==========================================================================
R2 Configurations
==========================================================================
Dialing Mode (dmode) : 1(ENBLOC)
R2 Line signaling type (stype) : E&M IMM
robbed bit reversion(rbr) : DISABLE(OFF)
Ringback tone send in alert (rsend) : ENABLE(ON)
Alert Msg send to network (asend) : ENABLE(ON)
Seizure Guard Time (t1) : 30 ms
Clear Foward Guard Time (t2) : 200 ms
Clear Foward Wait Guard Time (t3) : 30000 ms
Seizure Ack Guard Time (t4) : 1000 ms
Glare Guard Time (t5) : 360 ms
Answer Guard Time (t6) : 200 ms
Clear Backward Guard Time (t7) : 200 ms
Release Guard Time (t8) : 200 ms
Reanswer Guard Time (t9) : 200 ms
Release Wait Guard Time (t10) : 1000 ms
Block Detect Guard Time (t11) : 640 ms
Glare Detect Guard Time (t12) : 200 ms
If glare is detected, stay seizure(t13): 500 ms
==========================================================================
MAX:/CONFIG>
save
This command isn't recoverable. Are you sure(y/n)?y
Configurations in working memory is saved to NV-Memory.
Line signaling is E&M immediate-
start type. If there is any trouble in
interoperation, the value of each
timer is selected as default value.