5. You now need to enter / change some settings in the configure screen.
1.
You need to make sure you set the IP address to a static IP address.
2.
You need to enter in an IP address for this IP232 Ethernet to serial bridge.
This should be on the same network range as your computer & Z‐Wave Gateway. (e.g. 192.168.0.xx)
If you are unsure what IP settings to use you might need to contact the network administrator.
3.
You need to set the Baud rate to 9600 as that is what the D8/D16 communicates on.
4.
The TCP Port to accept connections should be set to 2401.
This port number can be anything, but recommended to use the default 2401.
5.
Once the settings have been entered, click on the ‘Send Settings (to IP232)’ button.
This will apply all the settings to the IP232 Ethernet to serial bridge.
6. Ensure the serial port is plugged into your D8/D16 panel. (which is supplied with the IP232 Module ‐ K‐6002D)
Black = PIN5
Blue = PIN2
White = PIN3
CONFIGURING D8/D16 SETTINGS
1. Enter installer programming mode on the panel keypad.
P [master code] E
(eg. P 123 E)
P [installer code] E
(eg. P 000000 E)
2. Enter P199E and enable the following options:
1E ON: Send Address.
2E ON: Send Time Stamp
3E ON: Send Alarms.
4E ON: Send Warnings.
5E ON: Send Access Events.
6E ON: Zone Seal State
7E ON: Send Test ASCII String
Summary of Contents for G1
Page 5: ...5 TYPICAL CONFIGURATION ...