5
Sound and Light Indication
Operation Status
LED
Buzzer
Stand by
Red light bright
-
Enter into programming mode
Green light Flashes on, then
RED Light flashes.
One beep
In the programming mode
Orange light bright
One beep
Operation error
-
Three beeps
Exit from the programming mode
Red light bright
One beep
Open lock
Green light bright
One beep
Alarm
Red light Shines quickly
Beeps
Basic Configure
Enter and Exit Program mode
Set Master Code
Programming Step
Keystroke Combination
1. Enter Program Mode
*
(Master Code) #
2. Update Master Code
0
(
New Master Code
)
#
(
Repeat New Master Code
)
#
(Master code is any 6 digits)
3. Exit Program Mode
*
Set the Working Mode
Notes: the XK Series device has 3 working modes: Standalone Mode, Controller Mode, Wiegand Reader Mode, choose
the mode you use. (Factory default is Standalone Mode / Controller Mode)
Programming Step
Keystroke Combination
1. Enter Program Mode
*
(Master Code) #
2. Standalone/Controller Mode
OR
2. Wiegand Reader Mode
7 2 #
(Factory default)
7 3 #
(Pre-Set in the factory after a ‘Factory default’)
3. Exit
*
Programming Step
Keystroke Combination
Enter Program Mode
*
(Master Code) #
(Factory default is 123456)
Exit Program Mode
*