Page 1: ...Innovative Electronic Solutions INSTALLation USER Manual 101 091 101 091B Ultraprox Bluetooth Keypad Reader Rev 1 0 ...

Page 2: ...1 CONTENTS INTRODUCTION 1 INSTALLATION 3 STANDALONE MODE 5 CONTROLLER MODE 11 WIEGAND READER MODE 13 ADVANCED APPLICATION 15 ...

Page 3: ...nrollment interlocked Wiegand 26 37 bits interface etc that are highlighter below Features Bluetooth Module to connect mobile App for opening door Fashion design all metal key button Metal Case Anti vandal Waterproof conforms to IP66 One relay 1 000 users 998 common users 2 panic users PIN length 4 6 digits Card type EM version 125KHz EM card Wiegand 26 37 bits input output Can be used as Wiegand ...

Page 4: ... seconds default 2 Amp Maximum Wiegand Interface Wiegand Input Wiegand Output Pin Output Wiegand 26 37 bits Factory Default Wiegand 26bits 4 bits 26 37 bits 26 37 bits 4 bits 8 bits ASCII 10 digits Virtual Number Note Set in the factory as 26 Bit Wiegand 10 Digit Virtual No If a factory reset is performed onsite then these settings need to be manually reset Environment Operating Temperature Operat...

Page 5: ... 12 28V AC DC Regulated Power Input Black AC DC 12 28V AC DC Regulated Power Input Pink GND Negative Pole Blue Relay NO Normally Open Relay Output install diode provided Purple Relay Common Common Connection for Relay Output Orange Relay NC Normally Closed Relay Output Install diode provided Yellow OPEN Request to Exit REX Input Pass Through Wiring Wiegand Reader or Controller Green Data 0 Wiegand...

Page 6: ...Combination 1 Enter Program Mode Master Code 2 Update Master Code 0 New Master Code Repeat New Master Code Master code is any 6 digits 3 Exit Program Mode Set the Working Mode Notes the XK Series device has 3 working modes Standalone Mode Controller Mode Wiegand Reader Mode choose the mode you use Factory default is Standalone Mode Controller Mode Programming Step Keystroke Combination 1 Enter Pro...

Page 7: ...be worked as Standalone Reader for single door Factory default mode 7 2 Connection Diagram Attention Install a 1N4004 or equivalent diode is needed when using a common power supply or the keypad might be damaged 1N4004 is included in the packing ...

Page 8: ...Auto ID Allows XK Series device to assign Card to next available User ID number OR 2 Add Card Select Specific ID Allows Master to define a specific User ID to associate the card to OR 2 Add Card by Card Number OR 2 Add Card Block Enrolment Allows Master to add up to 998 cards to the Reader in a single step Takes 2 minutes to program 1 Read Card The cards can be added continuously 1 User ID Read Ca...

Page 9: ...g Read Card Old PIN New PIN Repeat New PIN 2 Change PIN By PIN User ID Old PIN New PIN Repeat New PIN 3 Exit Delete Users Programming Step Keystroke Combination 1 Enter Program Mode Master Code Delete Card User Common 2 Delete Card By Card OR 2 Delete Card By ID number OR 2 Delete User By Card number 2 Read Card The cards can be deleted continuously 2 User ID 2 Input 8 10 digits Card number Delete...

Page 10: ...ination 1 Enter Program Mode Master Code 2 Card access OR 2 Card PIN access OR 2 Card or PIN access OR 2 Multi cards PINs access 4 0 4 1 4 2 4 3 2 9 Only after reading 2 9 cards or inputting 2 9 PINs the door can be opened 3 Exit Set Strike out Alarm The strike out alarm will engage after 10 failed card attempts Factory is OFF It can be set to deny access for 10 minutes after engaging or disengage...

Page 11: ...d user PIN or input Master Code To reset to factory default Add Master Cards Power off press the Exit Button hold it and power on there will be two beeps and the LED light turns into yellow release the exit button then read any two 125KHz EM cards the LED will turn into red means reset to factory default successfully Of the two cards reading the 1st one is Master Add Card the 2nd one is the Master...

Page 12: ... Wiegand input formats according to the Wiegand output format of the external Reader Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Wiegand input bits 8 26 37 factory default is 26bits 3 Exit Programming Basic Programming is the same as Standalone Mode There are some exceptions for your attention The XK Series device Connected with External Card Reader If EM card reader ...

Page 13: ...der Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 PIN input bits 8 4 or 8 or 10 factory default is 4bits Pre Set in the factory after a Factory default is 10 Bit Output format 3 Exit Remarks 4 means 4 bits 8 means 8 bits 10 means 10 digits virtual number Add PIN Users To add PIN users after enter into programming mode on the XK Series device PIN s can be input added on ...

Page 14: ...ontrol Yellow wire Buzeer control If you need to connect Brown Yellow wires When the input voltage for LED is low i e Connected to 0V the LED will turn to Green and when the input voltage for Buzzer is low i e Connected to 0V it will sound Set Wiegand Output Formats Please set the Wiegand output formats of Reader according to the Wiegand intput formats of the Controller Programming Step Keystroke ...

Page 15: ...of the Master Unit and the Accept Unit must be set to the same Program the transfer operation on Master Unit only If the Accept Unit is already with the users enrolled it will be covered after transferring For full 1000 users enrolled the transfer takes 3 minutes Set Transferring on Master Unit Programming Step Keystroke Combination 1 Enter the programming mode Master Code 2 Set transferring 9 6 W...

Page 16: ...Step 1 Enroll the users on Keypad A then transfer the users information to Keypad B by User Information Transfer funciton Step 2 Set both of the two readers A and B to Interlock function Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Interlocked OFF OR 2 Interlocked ON 9 0 factory default 9 1 3 Exit The interlock operation is finished When and only door 2 is closed the u...

Page 17: ...6 is the factory default master code Change the master code 0 new code repeat the new code code 6 digits Add card user 1 Read Card can add Cards continuously Add PIN user 1 PIN Delete user 2 Read Card for Card user 2 PIN for PIN User Exit from the programming mode How to release the door Card User Read card PIN User Input PIN ...

Page 18: ...tooth Keypad Reader Installation User Manual Rev 1 0 For the product 101 091 101 091B Ultraprox Bluetooth keypad reader www nesscorporation com National Customer Service Centre Ph 1300 551 991 customerservice ness com au ...