Doc ID. SG3PROG00103_03_2014.DOC
23
DEFALT
RESET TO FACTORY DEFAULTS
Erase devices and/or default options as required.
PHONE1, PHONE2 and CLIENT will only be cleared if programming timeout has not disabled
reprogramming of these options. SecurityGuard will jump to the start of PROGRAM mode,
displaying KEY 1.
ALL
Erases all programmed devices and defaults all options
OPTION
Defaults all option values
KEY
Erases all keys
SENSOR
Erases all detectors; defaults SENSOR 1 (main PIR)
P-EXIT
PROGRAM MODE EXIT/CONTINUE
•
Press ON to exit PROGRAM mode.
•
Press OFF to step to first program option.
•
If the OFF button is pressed, LEARN will be displayed. By then pressing ON, READY will
be flash and the unit will be ready to learn a new code (radio key or device)