16
TROUBLE SHOOTING GUIDE
******************************************************************************************************
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
Zone light on or long beeps
Zone detection device (eg.
Close door or window. Find
on Arming.
reed switch, movement
cause of movement.
detector) unsecured.
Number of beeps determine
which zone is unsecured.
10 beeps upon Arming.
Mains power off. Battery
Check plug pack is plugged
Mains light flashing
low.
in and power point on, or
Battery light flashing.
call Installation Company.
10 Beeps at any time
(as above)
(as above)
(mains / battery light flashing)
1 long beep during keypad
Invalid keypad entry.
Press END button and re-
entry.
enter.
Constant tone upon Arming.
Tamper, panic or 24 hour
Check panic button (If in-
zone unsecured.
stalled), or call Installation
Company.
2 second siren at end of
Zone unsecured before ex-
Re-enter premises, disarm
exit time.
piry of exit time.
system, check zone isolate
memory to determine zone
Constant tone on entering
Alarm occurrence since last
Check Alarm memory to
premises.
arming of panel.
determine zone at fault.
External strobe light flash-
Alarm occurrence since last
Check Alarm memory to
ing.
arming of panel.
determine zone at fault.
Siren sounding when sys-
Tamper, panic or 24 hour
Reset alarm by entering
tem disarmed.
zone activated.
code or activating key-
switch, check panic buttons
(if installed), or call Install-
ation Company.
Armed/monitor light flash-
Monitor mode entered by
Exit monitor mode.
ing.
mistake.
Zone Excluded light flash-
A zone has been excluded.
Check zone excluded
ing.
memory. Arm panel with all
zones secured.
Tamper light flashing.
Tamper unsecured.
Call Installation Company.
Alarm memory light flashing.
Alarm in memory.
Check alarm memory to see
cause of alarm.