12
EMERGENCY FUNCTIONS
******************************************************************************************************
For personal protection, the Control Panel
a) Audible - Activates sirens and will transmit
contains an INSTANT panic feature.
the alarm signal if monitored.
Panic can be used to;
b) Silent - Will transmit the alarm signal if
Scare away intruders inside or outside
monitored remotely.
your premises.
To activate emergency alarms:
Summon help from friends or
neighbours.
MEDICAL
enter
1E
FIRE
enter
2E
Test the operation of the siren.
PANIC
enter
3E
Three Emergency functions exist:
To SILENCE the siren, you must enter:
MEDICAL. A silent alarm that is only used if
(CODE) E
the Alarm system is monitored remotely
(eg. Central Station).
Panic cannot be used while the Panel is in
Program, Memory or Exclude mode
FIRE. An audible alarm that activates sirens and
will transmit the alarm signal if monitored
If you have the optional Remote Keyswitch,
remotely (eg. Central Station).
press the separate panic button fitted above the
keyswitch.
PANIC. This function may have been
programmed to be either;
EMERGENCY!
1. ENTER
3E
The siren will sound.
2. ENTER
(CODE) EThe siren will stop.
ZONE EXPANDER FUNCTIONS
******************************************************************************************************
These buttons are ONLY USED in conjunction
with the NESS 5000 Series Zone Expander to
address the sixteen additional zones.
(4) (END)
(6) (END)
Address first additional bank of 8 zone
Address the second bank of 8 zones