8
EXIT DELAY TIME
******************************************************************************************************
The Exit Delay Time is the time the Control
1. To view the current Exit Delay Time, enter:
Panel gives you to secure and depart the
premises after the Panel is Armed.
P 6E
The Exit Delay Time should be just long enough
2. The value programmed will be displayed via
to allow departure comfortably without rushing
the zone (1-8), battery (9) and mains (0)
and making mistakes.
lights. This display of the current value must
be complete before a new value can be
entered.
The Exit Delay Time can be set to a minimum of
3. To change the current value to say,
1 second up to a maximum of 99 seconds.
80 seconds enter:
80 E
Zone 8 light will flash on for 1 second followed
by the MAINS light (0) to indicate the new value
To VIEW Exit Delay Time ENTER
To CHANGE Exit Delay Time ENTER
(PROG) (6) (END)
(VALUE) (END)
MONITOR MODE 'TYPE
******************************************************************************************************
The 8 zone Control Panel provides an unique
The 4 different types of Monitor mode alarms
Monitor mode to ensure your security even
are:
while the Panel is disarmed and the premises
are occupied.
1 = Beeper warning for the duration of the panel
entry time, then full siren alarm. Used for
perimeter protection.
Typically, Monitor mode is used to monitor the
2 = Beeper and siren operate for 2 seconds
perimeter zones (doors, windows) of a house
only. Use this for medium security warnings or
while the occupants are at home or to monitor
as a walk test mode.
entry through front doors or fire doors in shops
and offices while the premises are in use.
3 = Full siren alarm immediately. Use this for
high security, such as monitoring fire doors etc.
4 = Zone number is beeped out only. Use this
You can program which zones are to be
for door opened warning.
monitored as well as select 1 of 4 different
types of Monitor alarms.
To select, say, Monitor mode 3, enter:
P7E 3E
When the above option is programmed into the
panel, zone light 3 will flash on for 1 second.
Talk to your security installation company
about your specific requirements.
To VIEW Monitor Mode Type ENTER
To CHANGE Monitor Mode Type ENTER
(PROG) (7) (END)