Pixie service manual
71
F U N C T I O N T E S T S
8.4.2 Test run
11) Open the valve and let the water flow
for approximately 10 sec out of the
drain hose.
12) Close the valve completely. The pres-
sure stabilizes after increasing briefly
between 16-19 bar (pressure check).
The pressure increases slowly with
increasing temperature. Should the
pressure exceed 23 bar, switch off
the coffee machine and release the
pressure by opening the valve.
11/ 12
10 sec
For better visibility
use a flashlight.
13) Check connections under pressure for
audible and visible leaks
- through opening in right housing
- through opening for capsule ejection.
Do not run the pump for more
than 50 sec with the valve
closed.
13
max.
50 sec
13