Pixie service manual
74
F U N C T I O N T E S T S
8.6
Protective earth (PE) continuity test
8.6.1 What is the protective earth continuity test about?
This test is only necessary
-
for class 1 equipment (three-wire power cord with protective earth)
-
after a repair whenever a general disassembly was performed.
Therefore all Pixie models have to be tested after general disassembly, except country-
specific models (USA, Canada, Japan) without a protective earth connection (refer to
"Wiring diagrams" on page 59 and following).
8.6.2 General
Legal regulation
In case of a repair/modification of the coffee machine, the repair centre is bound by law
to protect the user/consumer by
-
restoring the regular condition of the appliance and
-
performing the respective tests according to EN/IEC 60335-1 “Safety of household
and similar electrical appliances” and national regulations (e.g. DIN VDE 0701).
Description
Protective earth continuity measurements are made between the protective earth
terminal of the power plug and the thermoblock casing.
This test assures that
-
the ground (earth) connection does not have an interruption between the power plug
and the thermoblock
-
the permissible ground resistance is less than 0.3 Ohms (with a test current of
200 mA DC).
Test equipment
Special test equipment is needed that complies with the regulations to perform protec-
tive earth continuity measurements. Detailed requirements and tolerances must be veri-
fied by your local authorities or measurement supplier in any case.
Test report
For legal reasons a repair or test report should be prepared and filed with following infor-
mation
-
customer (name, address)
-
type and serial number of coffee machine
-
date of repair/test(s)
-
performed test(s)/measuring value(s)
-
used test equipment
-
signature
Ask
Nespresso
for
recommendations
about test equipment.
Summary of Contents for EF 280
Page 41: ...Pixie service manual 41 R E P A I R S Open latch with screwdriver Open latch with screwdriver...
Page 55: ...Pixie service manual 55 R E P A I R S Remove thermoblock 21 from functional block 24 21 24...
Page 80: ...Pixie service manual 80 E X P L O S I O N D R A W I N G S 9 2 EF 281 Explosion drawing...
Page 88: ...Pixie service manual 88 N O T E S 1 1 N O T E S...