background image

MANUAL FOR USE AND MAINTENANCE

EN LSC 050 06-2020

Summary of Contents for S50

Page 1: ...MANUAL FOR USE AND MAINTENANCE EN LSC 050 06 2020...

Page 2: ...ng at the end of its lifetime is organized and run by the importer distributor The user who should have to dispose of such equipment should get in touch with the importer distributor and follow the pr...

Page 3: ...t in place by the customer See chapter INSTALLATION REQUIREMENTS FOR THE USER The appliance must be installed where use and maintenance are restricted to trained staff CAREFULLY READ THE FOLLOWING WAR...

Page 4: ...the appliance itself especially in terms of safety and hygiene This appliance can be used by children aged from 8 years and above and person with reduced physical sensory or mental capabilities or la...

Page 5: ...ns are also available in an alternative format e g on a website Failure to comply with the above regulations could jeopardise the correct operation and safety of the appliance as well as its useful li...

Page 6: ...the spread of bacteria The appliance is supplied without water in the boiler This is to prevent serious damage if the appliance is exposed to low temperatures The appliance must only be supplied with...

Page 7: ...T WATER DELIVERY FOR HOT BEVERAGES 15 5 4 ELECTRIC CUP WARMER 16 5 5 ECONOMY MODE 17 5 6 WASHING THE GROUPS 18 5 7 BOILER WASHING FUNCTION 19 5 8 CLEANING FUNCTION 20 6 PROGRAMMING OF THE MACHINE 21 6...

Page 8: ...t steam lever 2 2 group display 3 Main display 4 1 group display 5 Right steam lever 6 Right steam wand 7 M A T steam wand 8 Water level indicator 9 Right front foot 10 Main switch 11 1 cup portafilte...

Page 9: ...ld white led for right side 18 RGB led for right side 19 RGB led for right back foot 20 RGB Led for right front foot LEGEND 21 RGB Led for left side 22 Cold white led for left side 23 RGB led for left...

Page 10: ...O P A Programming touch button B Date Time C Digital pressure gauge D Status bar E M A T 1 sel button F M A T 2 sel button G CLEAN button H Boiler wash button I Group cleaning button L ECO button M A...

Page 11: ...cycle is starting is a 30 seconds count down on the corresponding group Auto water refill according to the water refill system the symbol can be ON or OFF Water mains pressure indication the machine c...

Page 12: ...the Economy function is deactivated Indication of the boiler electric heater control the power input of the machine is run in standard mode Indication of the boiler electric heater control in case of...

Page 13: ...06 2020 7 a b c e d f LEGEND a Free Flow touch button b Long coffee button c Double long coffee button d Purge touch button e Double short coffee button f Short coffee button g Temperature SET ITC 3...

Page 14: ...plates Make sure that they are all readable and for this purpose clean or replace those which are damaged or not readeable both in the text and in the graphics To clean the labels or data plates use...

Page 15: ...ntion As the appliance has a weight higher than 30Kg it cannot be lifted by one person alone Note Proceed to dispose of the packaging materials as per norms in force in the destination country of the...

Page 16: ...CESSORIES supplied only on request of the customer I Water softener L Water mains impurity filter M Pressure Reducer N Detergent LEGEND 4 STARTING THE SYSTEM Open water mains tap Check any water leaks...

Page 17: ...APPLIANCE Press the main switch 10 pag 2 Attach the portafilter to the group Wait for the machine to reach the operating pressure indicated by the green triangle The machine refills the boiler with w...

Page 18: ...ly attach the portafilter to the group Place one or two coffee cups below the spout Press one of the preset dose buttons or the free flow delivery 1 3 4 5 Fill the portafilter with ground coffee and p...

Page 19: ...time in green on the left and the real extraction time in white on the right A progressive white circular bar will show if the preset time has been reached green triangle If it turns red it means tha...

Page 20: ...Or press the button on the bottom left hand side O page 4 to deliver mixed hot water The delivery stops at the end of the time programmed during the installation N B The temperature of the water deli...

Page 21: ...the lever of the steam wand to start heating the beverage At the end move back the lever to the initial position Note Do not deliver the steam before inserting the wand into the jug to avoid possible...

Page 22: ...r button The display shows a pop up that allows to modify the temperature of the cup tray Set the new temperature and push save or wait for the pop up to close With the cup warmer turned on the temper...

Page 23: ...e ECO button With the ECONOMY function active all delivery function of coffee tea and steam M A T are disabled The RGB LEDs on the feet and sides are in green The boiler temperature reaches 85 C Press...

Page 24: ...n to activate the GROUP CLEANING cycle The GROUP CLEANING cycle consists of 5 seconds of water delivery from the selected group followed by 5 seconds of STOP thus allowing the use of the brush to clea...

Page 25: ...he spout and then automatically refills the water into the boiler Press BOILER WASHING button again to interrupt the washing cycle in advance Place a container below the hot water spout to empty it fr...

Page 26: ...temporarily disables the capacitive display thus allowing to clean the glass Push the CLEANING button 1 Push YES For 30 the capacitive displays are disabled After completion the displays will show the...

Page 27: ...ndary menu SETTINGS TOOLS SETUP Scroll left to visualize the menu INFO CUSTOMIZATION TECHNICAL Compared to what is described below the programming may differ in some menus depending on the settings ma...

Page 28: ...enu Language and Date Time Select the language 6 2 LANGUAGE Push Save button The main display will power off and back on by viewing the HOME screen in the selected language Language function allows to...

Page 29: ...Push Date Time button 6 3 DATE TIME ByusingtheARROWSsetthecurrent DateTime Confirm by pressing Save button 1 2 3 EN LSC 050 06 2020 23...

Page 30: ...6 4 TIMER Push Tools button Push Timer button Select ON Timer function allows to turn on and off the machine automatically at a prearranged time Push Edit Events button 1 2 3 4 EN LSC 050 06 2020 24...

Page 31: ...ng on time and move the cursor to ON Confirm with Save To set the time and day of shutdown press Add event again Select the day and the time of shutdown and move the cursor to OFF Confirm with Save To...

Page 32: ...tching on time press yes Disable timer to force the switching on 6 5 COFFEE DELIVERY TIME CONTROL MENU Select Coffee extraction times Move the cursor to ON to activate the function Coffee delivery tim...

Page 33: ...the following delivery if the coffee extraction is within the range of time stored by the service during the installation phase the selected tolerance the progressive bar will be green Otherwise in c...

Page 34: ...6 6 SETUP MENU Push button to increase the boiler pressure Push button to decrease the boiler pressure Push Boiler pressure Push Setup button 6 7 BOILER PRESSURE 1 2 EN LSC 050 06 2020 28...

Page 35: ...6 8 COFFEE DOSES Push the button Start dose setup Attach the portafilter with the coffee to the 1st 2nd or 3rd group starting from the right and press the one short coffee button to start the delivery...

Page 36: ...utton to stop the coffee delivery Repeat the same procedure with the other buttons Press Stop at the end The group on the right copies the doses on the other groups In case you want to program the 2nd...

Page 37: ...r to start the water delivery Place a jug below the hot water spout Once the desired amount of water in the pot is reached press the same button to stop the water delivery and to memorize it Repeat th...

Page 38: ...ARE VERSIONS Push Software versions button Software versions menu allows to know the firmware versions of the various boards The display shows the firmware versions of power groups and ANDROID applica...

Page 39: ...IDE In the User guide menu it is possible to display the manual for use and maintenance 7 3 TUTORIAL On the Tutorial menu it is possible to display a series of videos related to the machine EN LSC 050...

Page 40: ...the energy consumption of the machine in KW h N B the displayed value may slightly differ from the amount of energy actually used 7 5 COUNTERS In the Counters menu you can check the number of coffee...

Page 41: ...COUNTERS In the Reset product counters menu it is possible to reset the partial coffee tea and steam M A T counters Enter the Reset product counters menu Push Reset button Push Yes button 1 2 3 EN LS...

Page 42: ...8 NUMBER OF SELECTIONS The Number of selections menu allows you to select the number of preset dose buttons on the group display Push Number of selections button Select 2 Selections or 6 Selections 1...

Page 43: ...6 dose selection touchpad layout 2 dose selections touchpad layout Select 2 Selections or 6 Selections and confirm with SAVE 3 EN LSC 050 06 2020 37...

Page 44: ...7 9 PURGE TIME The Time Purge menu allows you to set the purge button delivery time Push Purge Time button Select the required time and confirm with Save 1 2 EN LSC 050 06 2020 38...

Page 45: ...n the feet and side panels Select Led RGB The cursor on top allows you to turn the RGB LEDs on or off Select the desired colour Adjust the light intensity and confirm with Save The RGB LEDs on the sid...

Page 46: ...llows you to manage the white LEDs that illuminate the cup tray Select Led Cup Tray The cursor on top allows you to turn the Cup Tray LEDs on or off Select the light intensity of the LEDs and confirm...

Page 47: ...enu allows you to manage the white LEDs of the front LA SPAZIALE logo Select LED logo The cursor on top allows you to turn LA SPAZIALE logo on or off Select the light intensity and confirm with Save 1...

Page 48: ...ctions of the machine originating from components cases for which it is NOT possible to keep the other functions of the machine enabled These alarms cause subject to the following exceptions a BLOCK o...

Page 49: ...NOT REACHED If after 15 minutes from turning on the machine the boiler temperature sensor does not detect at least 80 C all machine functions are disabled 24 VAC VOLTAGE FAILURE AT THE EV SOLENOID VAL...

Page 50: ...messagesoccuraPOPUPshowing MACHINELOCKALARM isdisplayedinthemainDISPLAY followedbythedescription MACHINEALARM followedbythedescriptionofthealarm see image1 ThePOPUPstaysonforatimeof 30 afterwhichitdis...

Page 51: ...ter 5 seconds from the delivery start the pressure detected by the pump is 12BAR BOILER PRESSURE SENSOR FAULTY It occurs when the boiler pressure sensor has failed N B With active alarm thermoregulati...

Page 52: ...LED FLOW METER DOSING At the end of the delivery the POPUP disappears and there is no evidence of it on the main display ITC 3 0 TEMPERATURE PROBE FAILURE It occurs when the thermocouple of the I T C...

Page 53: ...is missing With active alarm the corrisponding group is deactivated same visualization of when ECO is actve with the symbol TRIANGLE with exklamation point active instead of the S50 logo You reset th...

Page 54: ...aintenance operations must be carried out by the user according to the manufacturer s instructions given here below Before performing any cleaning operation make sure the machine is unplugged from the...

Page 55: ...and another Clean the drip tray and the cup grid using the standard detergents available on the market if necessary After turning off the machine remove the shower heads using the wrench provided brus...

Page 56: ...amage We recommend not to use abrasive sponges that could damage the body panels EN LSC 050 06 2020 50 If the installation of a water softener has been recommended by the installation engineer because...

Page 57: ...La Spaziale S p A Via E Duse 8 40033 Casalecchio di Reno Bologna Italy 39 051 611 10 11 39 051 611 10 11 39 051 611 10 40 info laspaziale com Design by LA SPAZIALE S p A EN LSC 050 06 2020...