TRICON
®
SmartTrol
™
Installation and Maintenance Guide
11
Chapter 5: Specifications
This chapter provides the specifications for the TRICON
®
SmartTrol™.
Specification
Description
Housing
High-impact plastic case with NEMA 4X front panel.
Dimensions
Display
8-character, 0.55" high, 15-segment, red orange LED.
Input Power
110 VAC +/– 15% or 12 to 27 VDC.
Current
5.3 VA at rated AC voltage or maximum 280 mA DC.
Output Power (On
AC power units
only)
+12 VDC at 100 mA; Separate isolated 12 VDC at 100 mA to allow +/– 12 VDC
or +24 VDC, reg/- 5% worst case.
Temperature
l
Operating: +32° F (0° C) to +130° F (+54° C).
l
Storage: –40° F (–40° C) to +200° F (+93° C).
Memory
EEPROM stores all programming, display mode, and count data for a
minimum of 10 years if power is lost.
Reset
l
Front panel push button CLR - Resets displayed number and control
output.
l
Remote input (Terminal 5) - Open or 0 to 1 VDC (low), 3 to 30 VDC (high),
10K ohm input impedance to ground. Minimum pulse on / off time 5
msec.
Pulse Input
High impedance pulse input. Open or 0 to 1 VDC (low), 3 to 30 VDC (high),
10K ohm input impedance.
1KHz maximum speed (minimum on / off 25 usec).
Analog Output
4-20 mA sinking output, 3-24 VDC +/- 100 uA worst case.
Relay Contacts
10 amp, 120/240 VAC or 28 VDC.
Table 6 – Specifications