HP PROTECTUS
®
III (Turbine Side)
Size
Max
Flow
(GPM)
Max Continuous
Flow
(GPM)
Min Flow
(GPM)
Pulses / Gallon
Pulse Output @
Max Cont. Flow
(CPS)
Flow for 20
mA Output
(GPM)
4"
1,500
1,200
10
7.556
151.1
1,200
6"
3,750
3,000
20
0.7556
37.78
2,888
8"
5,000
4,000
35
0.0695
40.63
4,959
10"
8,000
6,500
50
0.5333
57.78
9,209
Table
27
–
HP
PROTECTUS
®
III
(Turbine
Side)
TRU/MAG™ High Frequency Output / K Factor
Meter
Size
Pulses per
Gallon
Pulses per Liter
Qmax* Gallons per Minute
Qmax* Liters per Minute
3"
25.228
6.665
600
2,271
4"
16.362
4.323
1,000
3,780
6"
6.307
1.666
2,400
9,462
8"
3.344
0.883
4,400
16,656
10"
2.150
0.568
7,000
26,496
Table 28 – TRU/MAG™ High Frequency Output / K Factor
* Flow rate at 150 Hz max pulse rate.
52
TRICON
®
SmartTrol™ Installation and Maintenance Guide
Appendix A: Specifications