Universal Wall-Mount Controller

BACnet Communication Module User Guide

 

www.neptronic.com

 

Page | 1 

 

Introduction  

The TUCB & TUHB Series Controller BACnet

®

 Communication Module User Guide provides information about using 

the controller with BACnet communications feature. The BACnet communication protocol for building automation and 
control networks enables communication between client devices within a network. The controller provides a BACnet 
network interface between BACnet client devices and Neptronic Controller series devices. It uses the BACnet Master 
Slave/Token Passing (MS/TP) protocol at the BACnet MAC layer. 

Pre-requisites 

The  BACnet  communication  user  guide  assumes  that  you  are  familiar  with  the  concepts  of  BACnet  and  its 
terminology. 

Advantages of BACnet  

BACnet enabled controllers have the following advantages: 

 

Quick Message Transmission.

  The  controller  uses  a  synchronous  implementation  for  BACnet  messages 

making  it  quick  and  efficient.  Each  BACnet  confirmed  service  request  is  answered  as  quickly  as  possible 
without using the 

Reply Postponed

 frame. The MS/TP implementation is performed within 

Tusage_delay

 of 

15 minutes to ensure a 

Tusage_timeout

 value within 20 minutes.  

 

MS/TP Support.

 The controller supports a Full Master Node state machine for MS/TP. The Max_Master and 

the instances are configured to the device object through 

BACnet  WriteProperty

 service or via the device's 

Programming Mode. The MAC address and the MS/TP baud rate setting of 9600, 19200, 38400, or 76800 are 
also set through the 

BACnet Write Property 

service or via the device's Programming Mode. In Programming 

mode,  the  device  is  configured  through  the  device’s  keypad.  For  more  information  about  the  WriteProperty, 
refer to 

Table 3 - Object Types Supported

 

BIBB Support

.  The  controller  functions  the  same  way  as  the  B-ASC  type  profile  server  and  supports  the 

specific BIBB as per their relevant definitions. 

o

 

DS-RP-B 

o

 

DS-RPM-B 

o

 

DS-WP-B 

o

 

DS-WPM-B 

o

 

DM-DCC-B 

o

 

DM-DDB-B 

o

 

DM-DOB-B 

o

 

DM-RD-B 

o

 

DM-TS-B 

o

 

DM-UTC-B 

o

 

DS-COV-B 

o

 

DS-COVP-B 

o

 

SCHED-WS-I-B 

 

Object Support

. The controller supports a fixed list of BACnet visible values, which appear as Present_Values 

of various BACnet standard object types in addition to a device object. For more information, refer to 

Table 3 - 

Object Types Supported

.  

 

Alarms

. The controller supports indication of various alarm conditions through value changes in properties of 

several objects. However, it does not generate BACnet event notifications.  

 

 

Summary of Contents for TUCB24C6X2

Page 1: ...versal Wall Mount Controller TUCB TUHB Series BACnet Communication Module User Guide TUCB24C6X2 with Internal Temperature Sensor 6 binary 2 analog outputs TUHB24C6X2 with Internal Temperature and Humi...

Page 2: ...guration 2 Configuration Options 3 Quick Setup 3 Manual Setup 3 MAC Address and Max_Master 3 Copy Config 4 Network Reset 4 Device Object Properties 5 Object Types Supported 6 Out of Service Property 7...

Page 3: ...nutes to ensure a Tusage_timeout value within 20 minutes MS TP Support The controller supports a Full Master Node state machine for MS TP The Max_Master and the instances are configured to the device...

Page 4: ...ually through the WriteProperty service to Device Object Object_Identifier The device s Object_Identifier is a combination of the Device Object_Type 8 and the Device_Instance 0 4194302 therefore its d...

Page 5: ...t guarantee efficient operation of the controller and other MS TP units on the MS TP network Some MAC address and Max_Master combinations are more efficient than others BACnet requires token passing u...

Page 6: ...iguration of a controller over the network to controllers of the same type using the Copy Config feature 1 Access Operation Mode jumper set to RUN position 2 Press and hold both function buttons for 5...

Page 7: ...Object Name and or device ID change Max_APDU_Length_Accepted Always 480 Segmentation_Supported 3 No Segmentation APDU_Timeout 6000 W Number_of_APDU_Retries Always 3 Local_Time 00 00 00 W Local_Date 0...

Page 8: ...Property section on page 7 for more information Object will automatically return to Normal after a programmable period of time Refer to Proprietary property 1002 of Device Object in Table 2 Device Ob...

Page 9: ...5 Out_of_Service property is not writable for MSV Program Description Reliability Program_Change Only LOAD and RESTART are supported for Program Change Use LOAD to apply the new firmware File Descript...

Page 10: ...o Units 0 Open 1 Close AI 2 AnalogInput2 Sensor reading value on analog input 2 Out of Service Cov Increment If a 10k type III sensor is used displays 0V Fault and Out of Service Status Flags are True...

Page 11: ...ocked to prevent the user from changing the setpoint BV 2 This object is commandable relinquish default will be saved to non volatile memory Present Value Relinquish_Default Cov Increment 50 F to 104...

Page 12: ...value must be bigger Present Value Cov Increment 0 to 250 seconds Resolution 5 seconds AV 46 Cfg_CoolingAntiCycleDelay Configuration value in mins to prevent the cooling outputs to cycle on and off Th...

Page 13: ...AV 81 Cfg_HumDeadBand Configuration value that represents the range at which the controller will not take action when below or above the humidity setpoint Present Value Cov Increment 0 RH to 5 RH Res...

Page 14: ...f demand at which the contact closes to energize the controlled element Present Value Cov Increment 15 to 80 Resolution 1 AV 116 Cfg_BinaryOutput1OpenPos Configuration value that indicates the percent...

Page 15: ...15 minutes Resolution 1 minute AV 165 CopyCfgStartAddress Represents the first address in the range of copied controllers while using the Copy Config option Present Value Cov Increment 0 to 254 Resol...

Page 16: ...t4 Contact status of the output 0 Open 1 Close Present Value 0 Open 1 Close BO 5 BinaryOutput5 Contact status of the output 0 Open 1 Close Present Value 0 Open 1 Close BO 6 BinaryOutput6 Contact statu...

Page 17: ...er internal or external Only available on model TUHB24C6X2 Present Value 0 Intern Sensor 1 Extern Sensor BV 26 Cfg_HumSetPointLock Configuration value to prevent the user from changing the relative hu...

Page 18: ...ed When set to 1 Reverse the contact is considered Normally Closed Present Value 0 Direct 1 Reverse BV 61 Cfg_BinaryOutput2Direction See BV 60 Present Value 0 Direct 1 Reverse BV 62 Cfg_BinaryOutput3D...

Page 19: ...at BV 3 BV 21 BV 98 and MSV 20 Auto Controller mode changes automatically between heating and cooling in operation when there is a cooling or heating demand Heating Controller is in heating in operat...

Page 20: ...s in night setback mode 3 Override Zone is in night setback mode but put back to day operation for a maximum pre determined time set at AV 85 Read Only 1 Day 2 Night 3 Override MSV 20 Cfg_Sequence Sel...

Page 21: ...lter Controller activates an alarm to indicate that the filter is dirty 15 Flow Switch Controller activates an alarm to indicate that there is no airflow 16 Overheat Controller activates an alarm to i...

Page 22: ...e 1 OFF 2 Change Over With Fan 3 Cooling1With Fan 4 Cooling2With Fan 5 Heating1With Fan 6 Heating2With Fan 7 Heating2 8 Cooling1Heating1With Fan 9 Humidify With Fan 10 CO2Alarm MSV 57 Cfg_AnalogOutput...

Page 23: ...demand 2 Display Setpoint Demand TUxB will display the actual setpoint and cooling heating demand 3 Display Temp TUxB will display the actual temp but no demand 4 Display Setpoint TUxB will display t...

Page 24: ...beau blvd Montreal Qc H4N 1R6 Canada www neptronic com Toll free in North America 1 800 361 2308 Tel 514 333 1433 Fax 514 333 3163 Customer service fax 514 333 1091 Monday to Friday 8 00am to 5 00pm E...

Reviews: