background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPANY PROFILE 

Northern Electric & Power Inc. (NEP) was founded in the United States and has 

manufacturing  and  R&D  facili

es  in  China.  The  mission  of  the  company  is  to 

develop cu

ng-edge clean energy technologies and provide state-of-the-art solar 

inverter products to its customers. The 

rst round of investment to the company 

was US$20 Million, with a planned total investment of US$50 Million. The company 

is headquartered in the city of Tsingtao, a major industrial center and trading port 

in the northeastern China. The company campus occupies more than 18 acres in 

the  Tsingtao  Export  Processing  Zone,  and  has  more  than  650,000  square  feet 

building space. The campus is planned to be connected through a micro smart grid 

demo community and powered by electricity from solar, wind and micro turbines. 

Outside China, the company has opera

on o

ces in Chicago, U.S. and Vancouver, 

Canada. 
The technology founders of the company are well-known experts in the 

elds of 

power  electronics,  automa

c  control,  signal  processing,  and  communica

ons.   

Each of the founders has mul

ple U.S. and world patents in their specialty areas.   

They received Ph.D. degrees from top universi

es in North America, and each has 

more  than  10  years  engineering  and  management  experiences  in  leading  U.S. 

companies.     
NEP has a complete product line of grid-

ed solar inverters, including 180W~500W 

micro inverters, 1.5kW~5kW single phase solar inverters, and 10kW~500kW three-

phase  solar  inverters.  Field  deployment  results  demonstrated  high  system 

e

ciency and reliability of NEP solar inverters. 

NEP  is  commi

ed  to  develop 

Clean,  Reliable,  A

ordable  and  E

cient

  (CARE) 

products for worldwide customers. 

 

01 

0 1 

Summary of Contents for BDM-300X2-208A

Page 1: ... 3252 FAX 81 092 433 3171 China Address No 1 Anhe Rd Tsingtao Export Processing Zone Tsingtao China 266113 TEL 86 532 87963900 FAX 86 532 81100917 Email info northernep com Web h p www northernep com h p www nep japan com h p www micro inverter jp Rev 2017 01 12 BDM 300X2 240A D BDM 300X2 208A D BDM 300X2 AU D BDM 300X2 EU D Installa on and Opera on Manual ...

Page 2: ...on Procedure Step 1 Install the AC Branch Circuit Junc on Box Step 2 A ach the BDM 300X2 to the Racking Step 3 Connect the BDM 300X2 Wiring Harnesses Step 4 Ground the System Step 5 Complete the connec on map and connect the PV Modules 5 COMMISSIONING 6 OPERATING INSTRUCTIONS 7 TROUBLRSHOOTING MAINTENANCE 8 SPECIFICATION 9 WARRANTY AND PRODUCTION INFORMATION CONTENTS 01 02 02 02 02 02 03 03 04 04 ...

Page 3: ...mmunity and powered by electricity from solar wind and micro turbines Outside China the company has opera on offices in Chicago U S and Vancouver Canada The technology founders of the company are well known experts in the fields of power electronics automa c control signal processing and communica ons Each of the founders has mul ple U S and world patents in their specialty areas They received Ph D d...

Page 4: ...NVERTER SHOULD BE MODIFIED ALL INSTALLATION SHOULD FOLLOW THE LOCAL ELECTRIC CODES FURTHER PROTECTION ON THE AC WIRING FROM THE INVERTERS SHOULD BE PROVIDED AND MAY BE REQUIRED BY LOCAL AND NATIONAL WIRING REGULATIONS THIS PROTECTION IS LIKELY TO INCLUDE RESIDUAL CURRENT DEVICES EARTH FAULT MONITORS AND CIRCUIT BREAKERS THIS PRODUCT MAY CAUSE AC CURRENT WITH A DC COMPONENT IF A RESIDUAL CURRENT OP...

Page 5: ...st prac ce to install surge protec on as part of any solar installa on Installa on of surge protec on devices should follow vendor instruc ons Installa on Procedure WARNING DO NOT CONNECT BDM 300X2 TO THE UTILITY GRID OR ENERGIZE THE AC CIRCUIT S UNTIL YOU HAVE COMPLETED ALL OF THE INSTALLATION PROCEDURES AS DESCRIBED IN THE FOLLOWING SECTIONS Installing the BDM 300X2 Micro inverter System involve...

Page 6: ...of these loca ons using hardware recommended by your module racking vendor Step 3 Connect the BDM 300X2 Wiring Harnesses Each BDM 300X2 comes with one 3 pin bulkhead receptacle mounted on the case The three pins of this connector are for phases L1 L2 and ground This AC connector is oppositely sexed with the connector at the end of the extension cable from the trunk cable through a T connector Plug...

Page 7: ...p you create Complete the connec on map Each BDM 300X2 has a removable serial number label located on the moun ng plate Enter this serial number into the BDG 256 and correspond it to a number in the connec on map Connect the PV Modules Completely install all BDM 300X2 and all system inter wiring connec ons prior to installing the PV modules 1 Mount the PV modules above their corresponding BDM 300X...

Page 8: ...roducing power The LED light is on by 1 second and off by 1 second Orange not communica ng to BDG 256 Green communica ng to BDG 256 Status grounding fault The LED light is in solid red color In case of fault BDM 250 has mul ple protec ve func ons and stops output power The fault message may be sent to a connected BDG 256 gateway through power line communica on The error message is displayed on the ...

Page 9: ...ch micro inverter system to block interference from adjacent other systems 7 If the problem persists please call customer support at NEP WARNING DO NOT ATTEMPT TO REPAIR THE BDM 300X2 IT CONTAINS NO USER SERVICEABLE PARTS IF TROUBLESHOOTING METHODS FAIL PLEASE RETURN THE BDM 300X2 TO YOUR DISTRIBUTOR FOR MAINTENANCE Disconnec ng a BDM 300X2 from the PV Module To ensure the BDM 300X2 is not disconn...

Page 10: ...Display LED LIGHT LED LIGHT Communica ons POWERLINE POWERLINE Dimension D W H mm 277 132 50 277 132 50 Weight Kg 2 9 2 9 Per IEEE 1547A MODEL BDM 300X2 AU D BDM 300X2 EU D INPUT DC Max Recommended PV Power Wp 340 x 2 Vmax PV absolute maximum Vdc 60 PV Input Opera ng Voltage Range Vdc 22 55 Maximum Opera ng PV Input Current Adc 12 x 2 MPPT Tracking Accuracy 99 5 Isc PV absolute maximum Adc 14 x 2 M...

Page 11: ...ogical infesta ons or input voltage that creates opera ng condi ons beyond the maximum or minimum limits listed in the NEP product specifica ons including high input voltage from generators and lightning strikes c the product if repairs have been done to it other than by NEP or its authorized service centers herea er ASCs d the product if it is used as a component part of a product expressly warran...

Page 12: ...or Code s Brief Fault Descrip on and Photos monitoring gateway is required for verifica on Installa on Informa on Modules Used Modules Quan ty Inverters quan ty per string Installa on Company Name Installer Name For the informa on on our warranty terms and condi ons please see our website www northernep com en All fields must be completed in order to process claim Customer Signature Date All rights ...

Page 13: ...12 0011 福岡市博多区博多駅前 3 10 24 藤井ビル 1F TEL 81 092 433 3252 FAX 81 092 433 3171 China Address No 1 Anhe Rd Tsingtao Export Processing Zone Tsingtao China 266113 TEL 86 532 87963900 FAX 86 532 81100917 Email info northernep com Web h p www northernep com h p www nep japan com h p www micro inverter jp ...

Reviews: