8. SPECIFICATION
MODEL
BDM-300X2-240A(-D) BDM-300X2-208A(-D)
INPUT(DC)
Max Recommended PV Power (Wp)
340 x 2
340 x 2
Max DC Open Circuit Voltage (Vdc)
60
60
Max DC Input Current (Adc)
12 x 2
12 x 2
MPPT Tracking Accuracy
>99.5%
>99.5%
MPPT Tracking Range (Vdc)
22-55
22-55
OUTPUT(AC)
Peak AC Output Power (Wac)
550
550
Rated AC Output Power (Wac)
500
500
Nominal Power Grid Voltage (Vac)
240
208
Allowable Power Grid Voltage (Vac)
211-264
(Adjustable
*
)
183-228
(Adjustable
*
)
Allowable Power Grid Frequency (Hz)
59.3-60.5
(Adjustable
*
)
59.3-60.5
(Adjustable
*
)
THD
<3%
(at rated power)
<3%
(at rated power)
Power Factor
>0.99
(at rated power)
>0.99
(at rated power)
SYSTEM
EFFICIENCY
CEC E
ffi
ciency
95.5%
95.5%
Night Time Tire Loss (W)
0.11
0.11
PROTECTION
FUNCTIONS
Over/Under Voltage Protec
�
on
Yes
Yes
Over/Under Frequency Protec
�
on
Yes
Yes
An
�
-Islanding Protec
�
on
Yes
Yes
Over Current Protec
�
on
Yes
Yes
Reverse DC Polarity Protec
�
on
Yes
Yes
Overload Protec
�
on
Yes
Yes
Ground Fault Detec
�
on
Integrated
Integrated
Protec
�
on Degree
NEMA-6
NEMA-6
Environment Temperature
-40
℃
~ +65
℃
-40
℃
~ +65
℃
Opera
�
ng Temperature
-40
℃
~ +85
℃
-40
℃
~ +85
℃
OTHER
PARAMETERS
Display
LED LIGHT
LED LIGHT
Communica
�
ons
POWERLINE
POWERLINE
Dimension (D-W-H mm)
277*132*50
277*132*50
Weight (Kg)
2.9
2.9
(* Per IEEE 1547A)
MODEL
BDM-300X2-AU(-D)
BDM-300X2-EU(-D)
INPUT(DC)
Max Recommended PV Power (Wp)
340 x 2
Vmax PV (absolute maximum) (Vdc)
60
PV Input Opera
�
ng Voltage Range (Vdc)
22-55
Maximum Opera
�
ng PV Input Current (Adc)
12 x 2
MPPT Tracking Accuracy
>99.5%
Isc PV (absolute maximum) (Adc)
14 x 2
Maximum Inverter Backfeed Current to the Array (Adc)
0
OUTPUT(AC)
Peak AC Output Power (W)
550
Rated AC Output Power (W)
500
Nominal Power Grid Voltage (Vac)
230
Nominal Output Current (Aac)
2.17
Current (inrush) (Peak and Dura
�
on)
24A, 15us
Nominal Frequency (Hz)
50
Power Factor
>0.99
(at rated power)
Maximum Output Fault Current (Aac)
4.4A peak
Maximum Output Overcurrent Protec
�
on (Aac)
10.0
SYSTEM
EFFICIENCY
CEC E
ffi
ciency
95.5%
Night Time Tare Loss (W)
0.11
PROTECTION
FUNCTIONS
Over/Under Voltage Protec
�
on
Yes
Over/Under Frequency Protec
�
on
Yes
An
�
-Islanding Protec
�
on
Yes
Over Current Protec
�
on
Yes
Reverse DC Polarity Protec
�
on
Yes
Overload Protec
�
on
Yes
Ground Fault Detec
�
on
Integrated
Protec
�
ve Class
I
IP Ra
�
ng
IP66 / IP67
Environment Temperature
-40
℃
~ +65
℃
Opera
�
ng Temperature
-40
℃
~ +85
℃
OTHER
PARAMETERS
Display
LED LIGHT
Communica
�
ons
POWERLINE
Dimension (D-W-H mm)
277*132*50
Weight (Kg)
2.9
15
14