USER MANUAL
INSTALLATION
5
NEOFOLD S
VERSION:
NLF_PB-S-2015-1S-GB
29
Electric connection
5.5.2
Check that the electric line is able to carry the power of the machine.
Electric hazards. Before making any connections to the mains make sure the system has
been grounded.
Select a mains to supply the machine.
Connect fed cable to socket with proper characteristics and placed near the machine.
Switch on the voltage powering the machine.
Electric hazards. Before making any connections to the mains make sure the system has
been grounded.
Section the electric line that supplies the machine.
If the sectioning device is the electric plug, the relative outlet must be easily accessible
and near the machine.
Return voltage to the electric line that supplies the machine.
The electric system supplying the machine must be equipped with:
Protection against overcurrents, via devices that have operating current, dimensioned
by considering maximum machine absorption.
An operating device for isolation (differential) failures, with rating suitably dimensioned
for the machine type.
An appropriate external equipotential protection circuit (grounding) that complies with
current legal regulations in the place where the machine is installed.
Testing 5.5.3
Before using the machine continuously check the general functioning of the machine by
doing some sample folding.
If there are any vibrations or unusual noise, immediately turn off the machine and seek for
the problem consulting the chapter
Diagnostic
.
If on the other hand, an alarm code appears on the display, consult chapter
09 Alarm
messages /signals
of this manual
and follow the procedures indicated.