USER MANUAL
DIAGNOSTICS
8
NEOFOLD S
VERSION:
NLF_PB-S-2015-1S-GB
43
Blade activation time setting test (17)
8.2.7
Press
key
9
until number
17
appears on the display (odd folding).
Press
key
7
to start the real test. The number of the parameter of the odd folding
clutch will appear (parameter 12).
Keys
8a
and
8b
increase/decrease the activation time-parameter for the odd
folding clutch.
Press
key
10
to enable/disable the test.
If the parameter value is high the time needed for the activation of
the odd folding clutch is very high, the blade rests on the rollers
for too long and could therefore stop the motor. If the motor stops,
press key
10
to deactivate the motor, decrease the parameter
value and try to start the motor again. We recommend to increase
the parameter value no more than 5 steps at a time. The new
parameter value is memorised each time key
10
is pressed
Press
key
9
again to stop the test
17
7
9
10
8a
8b