USER MANUAL
DIAGNOSTICS
8
NEOFOLD S
VERSION:
NLF_PB-S-2015-1S-GB
42
Motor test (15)
8.2.5
Press
key
9
until number
15
appears on the display.
Press
key
7
to start the real test.
Press
key
10
to enable/disable the engine.
The display shows:
0
= disabled
1
= enabled
Press
key
9
again to stop the test.
Motor test (16)
8.2.6
Press
key
9
until number
16
appears on the display.
Press
key
7
to start the real test.
Press
key
10
to enable/disable the motor.
The motor will run cycles of a number of steps equal to
the double length of the folding 190-mm. After every
running cycle the number which appears on the display
increases. If key
10
is pressed the motor is turned off.
When key
10
is pressed again the engine restarts.
Press
key
9
again to stop the test.
15
9
7
10
16
7
9
10