USER MANUAL
INSTALLATION
5
NEOFOLD S
VERSION:
NLF_PB-S-2015-1S-GB
28
Placing of the machine
5.5
Characteristics of the area the machine is placed in
5.5.1
Power supply
The area where the machine is installed must be equipped with the power supply
connections described in
3.2 Power supply data
.
Space requirements
For the normal use of the machine and the loading and unloading operations, it is
important to have an area directly proportional to the size of the media to laminate, or of
the panels for assembly operations, see Section 3.1.1
"Work Space"
.
Protection from atmospherics
The machine must be placed in a suitably protected room, away from atmospherics.
Floor requirements
Prepare the stable horizontal surface of the machine keeping in mind the mass of the
machine itself. Also take into account all extra accessories.
Optimum stability and use conditions are achieved with a maximum levelness error of ±
… mm/m. The machine must also be stabilized via the blocking of the four feet to the floor
so that the transportation wheels are slightly raised. Also the maximum slope of the floor
must not exceed a 10° slant.
Lighting
In the interests of the safe use and maintenance of the machine, it is necessary to have
good lighting (approximately 200 - 600 lux ) according to UNI10380:1994 standard.
Atmospheric characteristics of the area
Allowed Temperature: from 18°C to 35°C
Allowed humidity: from 30 % to 80 %.without condensate. Ideal humidity ~55%, with
max temperature 40°C.
General operating features
Do not use the machine in explosive atmospheres.
Do not use the machine near acids, corrosive substances, salt, etc.
Do not use the machine near ionizing and non ionizing radiations (X-rays,
microwaves, ultra-violet rays).