Part No. 729-110-040 Rev. 1.41 | June 2016
© 2016 Nelson Stud Welding, Inc. All Rights Reserved.
33
5.4.2 Maximum Welding Output Voltage
Check with Nelson representative for a Weld Cable Length calculator.
Nelweld N550c Rated Output Voltage (
Figure 7
) is
40V.
5.4.3 Supply Cable Lengths
Based on 3% drop and maximum 7% below nominal at mains connection during weld.
The same guideline applies to power drops from the mains high current breaker box or fuse box to disconnect
boxes and/ plug in for machine connection.
115 VAC Domestic
Up to X feet
AWG Cable, copper
35
12
60
10
230 VAC Export
Up to X feet
AWG Cable, copper
mm2, copper
35
14
2
60
12
3.5