Part No. 729-110-040 Rev. 1.41 | June 2016
© 2016 Nelson Stud Welding, Inc. All Rights Reserved.
41
6
Operational Function Codes & Error Codes
6.1
Function Codes
FIRMWARE VERSION 1.02
F Code
Description
Possible Values
Default
Unit
Notes
F0
Language
ENGLISH
ENGLISH
x
F1
Error Display
E--- to E021
E---
x
F2
Plunge Short Circuit
On-Time
0 to 100
20
ms
F7
Calibration Values
0 to 200
100
Clock
Cycles
Used by manufacturing; Do not
change.
F8
Chuck Saver
OFF ON
ON
X
F9*
Gas Enable
OFF ON
OFF
X
F10*
Gas Preflow Time
10 to 2000
500
ms
F11*
Gas Postflow Time
10 to 2000
500
ms
F12*
Stud Feed Enable
OFF ON
OFF
X
F13*
Stud Feed Time
10 to 2000
50
ms
Pulse width of stud feed signal.
This only applies when Stud Feed is
enabled.
F14*
Stud Feed Normal
Level
NORMAL CLOSED,
NORMAL OPEN
NORMAL
OPEN
X
This only applies when Stud Feed is
enabled.
F15*
Stud Feed Style
AFTER CONTACT
BREAK, AFTER
WELD
AFTER
CONTACT
BREAK
X
When to get the signal. This only
applies when Stud Feed is enabled.
F16*
Stud Feed on Air
Trigger
OFF ON
OFF
X
To feed a stud even when triggering
the gun while not welding. This only
applies when Stud Feed is enabled.
F17
Loadbank Enable
OFF
OFF
x
For manufacturing. This is a read-
only function used for burn-in
testing.
F19
Lock Mode
1 to 1
1
x
Mode 1: Use lock key to toggle
blocking on all keys - no password
protection.
Summary of Contents for ArcCharger N550C DOMESTIC
Page 18: ...Part No 729 110 040 Rev 1 41 June 2016 2016 Nelson Stud Welding Inc All Rights Reserved 17 ...
Page 60: ...Part No 729 110 040 Rev 1 41 June 2016 2016 Nelson Stud Welding Inc All Rights Reserved 59 ...
Page 62: ...Part No 729 110 040 Rev 1 41 June 2016 2016 Nelson Stud Welding Inc All Rights Reserved 61 ...
Page 64: ...Part No 729 110 040 Rev 1 41 June 2016 2016 Nelson Stud Welding Inc All Rights Reserved 63 ...