10.6. Installing the actuator and rod (or transmission) with a connection bar
Skyro 850 actuators can be connected in tandem using a rod without a motor, by
means of a mechanical connection bar. The movement of one actuator is mechanically
linked to the rod in order to transmit motion in a uniform manner and at the same
speed.
Two or more actuators can be installed on the window frame, with one or more Syncro³
version motors, depending on the force requirements.
Assemble as follows:
A. Mark the assembly distance between centres for the two actuators out onto the
frame in accordance with the measurements in the above table.
B. Place the support brackets of the actuator into position, mark
out the holes for drilling, drill the frame and mount the brackets
(see “Assembly for outward opening windows” for details).
C. Place the front brackets into position, mark out the holes for
drilling, drill the frame and mount the front brackets (see
“Assembly for outward opening windows” for details).
D.
Mount the actuators
E. Mount the connection bar as follows:
Insert the connection bar first into one of the actuators, and then into the second
actuator. Make sure the bar protrudes at least 2 mm from each actuator
(Fig. 7)
.
Mount and screw the M8x14 mm flat headed screw
(
provided with connection bar
), into the two ends of the bar
to prevent the bar from slipping out.
DISTANCE BETWEEN THE CENTRES OF THE CONNECTION BARS
Code
Description
Length of bar
(mm)
“D”
distance between
centres
4010009
Connection bar 1000 mm length
1.035
1.000
4010010
Connection bar 1500 mm length
1.535
1.500
4010011
Connection bar 2000 mm length
2.035
2.000
4010011
Connection bar 2500 mm length
2.535
2.500
For special measurements, consult the manufacturer
The drawing below shows an installation example with various push point solutions, with
actuators and rods on a large window or on “strip” windows. It should be noted that up to a
maximum of 8 Syncro actuators (4 for 230V) can be fitted, with various rod solutions for
additional push points.
Fig. 7
Two or more Syncro³ version
motors in tandem
11. ELECTRICAL CONNECTIONS
Appliances are equipped with cable manufactured in accordance with safety standards and
protection against radio disturbances.
E
ACH ACTUATOR MODEL MUST USE ITS OWN SPEC
Before performing the electrical connection consult the table below and check
correspondence between the feeder cable and the tension data on the actuator label.
Tension
Cable length
110-230V~ 50/60Hz
2 m
110-230V~ 50/60Hz
Syncro
3
2,5 m
24V
Syncro³
24V
RWA
2 m
If feeder cables require extending to the control button for low voltage actuators (24V
cable sections should be selected accordingly. Conductor sections are indicated in the
table on page 10
(Selection of cable section)
IMPORTANT FOR PRODUCT SAFETY:
in 24V
actuators, wire Green if not used must be insulated.
14
Two or more Syncro³ version
Two or more Syncro³
version 1 rod
with a connection bar in
tandem
One motor + 1 rod +
connection bar in tandem
ELECTRICAL CONNECTIONS
Appliances are equipped with cable manufactured in accordance with safety standards and
against radio disturbances.
UST USE ITS OWN SPECIFIC CABLE
.
Before performing the electrical connection consult the table below and check
correspondence between the feeder cable and the tension data on the actuator label.
Cable length
Number of
wires
Wire colours
2 m
3
L
IGHT
B
LUE
B
LACK
B
ROWN
2,5 m
4
L
IGHT
B
LUE
B
LACK
B
ROWN
2 m
3
R
ED
B
LACK
cables require extending to the control button for low voltage actuators (24V
cable sections should be selected accordingly. Conductor sections are indicated in the
Selection of cable section)
.
IMPORTANT FOR PRODUCT SAFETY:
actuators, wire Green if not used must be insulated.
One motor + 1 rod +
connection bar in tandem
Appliances are equipped with cable manufactured in accordance with safety standards and
Before performing the electrical connection consult the table below and check
correspondence between the feeder cable and the tension data on the actuator label.
Colour of wires used
for notification
-
G
REEN
G
REEN
cables require extending to the control button for low voltage actuators (24V
),
cable sections should be selected accordingly. Conductor sections are indicated in the
actuators, wire Green if not used must be insulated.