INSTALLER INSTRUCTIONS

 

nekos

 products have been manufactured in accordance with safety standards and conforms to the 

stipulations of current standards in force. 
When correctly assembled, installed and used according to the present instructions, they will not 
generate any danger for persons, animals or items. 

 

Symbols used in the manual

 

 

DANGER

 

This  indication  draw  the  attention  about  potential  dangers  for 
health of peoples and animals.

 

Contents 

1.  SECURITY RULES ................................
2.  FORMULAS AND RECOMME

2.1. Calculation of opening / closure force
2.2. Maximum opening in accordance with sash height

3.  TECHNICAL INFORMATIO
4.  CONSTRUCTION AND REG
5.  USE OF ACTUATOR IN SYNCRO³ VERSION

5.1.  Recognition ................................
5.2.  Use of a Syncro³-version actuator

6.  ID PLATE AND MARKING DATA
7.  TECHNICAL DATA ................................
8.  ACTUATOR DIMENSIONS
9.  ELECTRICAL POWER SUP

9.1.  Selection of power cable section

10. INSTRUCTIONS FOR ASS

10.1.  Preparation of actuator for assembly
10.2.  Calculation of the number of push / retention points
10.3.  Assembly with outward opening window
10.4. 

Installation on domed rooflights, dormers or industrial skylights

10.5.  Assembly with opening
10.6. 

Installing the actuator and rod (or transmission) with connection bar

11. ELECTRICAL CONNECTIO

11.1.  Connections of SKYRO 850
11.2.  Connections of SKYRO 850 SYNCRO³

12. PROGRAMMING THE ACTU

12.1. 

RESET

 Procedure ................................

12.2.  Closing stroke-end ................................
12.3.  Overlap acquisition ................................
12.4.  LED Light signals ................................

13. CHECKING FOR CORRECT
14. EMERGENCY MANOEUVRES
15. TROUBLESHOOTING ................................
16. ENVIRONMENTAL PROTEC
17. CERTIFICATE OF GUARANTEE
18. DECLARATION OF INCORPORATION (FOR A PARTLY COMPLETED MACHINE) 

AND EC DECLARATION OF CONFORMITY

 

INSTALLER INSTRUCTIONS

 

products have been manufactured in accordance with safety standards and conforms to the 

stipulations of current standards in force.  
When correctly assembled, installed and used according to the present instructions, they will not 
generate any danger for persons, animals or items.  

Symbols used in the manual 

This  indication  draw  the  attention  about  potential  dangers  for 
health of peoples and animals.

 

................................................................................................

FORMULAS AND RECOMMENDATIONS FOR INSTALLATION ................................

Calculation of opening / closure force ................................................................
Maximum opening in accordance with sash height ................................

TECHNICAL INFORMATION ABOUT FUNCTION ................................
CONSTRUCTION AND REGULATORY REFERENCES ................................
USE OF ACTUATOR IN SYNCRO³ VERSION ................................

................................................................................................

version actuator ................................................................

DATA ................................................................

................................................................................................

ACTUATOR DIMENSIONS ................................................................
ELECTRICAL POWER SUPPLY ................................................................

Selection of power cable section ................................................................

INSTRUCTIONS FOR ASSEMBLY ................................................................

Preparation of actuator for assembly ................................................................
Calculation of the number of push / retention points ................................
Assembly with outward opening window ................................

Installation on domed rooflights, dormers or industrial skylights

Assembly with opening inwards ................................................................

Installing the actuator and rod (or transmission) with connection bar

ELECTRICAL CONNECTIONS ................................................................

SKYRO 850 ................................................................
SKYRO 850 SYNCRO³ ................................

PROGRAMMING THE ACTUATOR ................................................................

................................................................
................................................................

................................................................

..............................................................................................

CHECKING FOR CORRECT ASSEMBLY ................................................................
EMERGENCY MANOEUVRES, MAINTENANCE OR CLEANING ...............................

................................................................................................

ENVIRONMENTAL PROTECTION ................................................................
CERTIFICATE OF GUARANTEE ................................................................
DECLARATION OF INCORPORATION (FOR A PARTLY COMPLETED MACHINE) 

EC DECLARATION OF CONFORMITY ..............................................................

INSTALLER INSTRUCTIONS 

products have been manufactured in accordance with safety standards and conforms to the 

When correctly assembled, installed and used according to the present instructions, they will not 

This  indication  draw  the  attention  about  potential  dangers  for  safety  and 

....................................... 4 

.................................. 5 

....................................... 5 

................................................... 5 

........................................................ 5 

............................................... 6 

.............................................................. 7 

........................................... 7 

......................................... 7 

.................................................. 7 

....................................... 8 

........................................................... 9 

................................................... 9 

......................................... 10 

............................................. 10 

................................. 10 

.......................................... 11 

............................................................ 11 

Installation on domed rooflights, dormers or industrial skylights

 ............................. 12 

........................................ 12 

Installing the actuator and rod (or transmission) with connection bar

 ...................... 13 

................................................... 14 

.............................................. 15 

............................................................. 15 

............................................ 16 

............................................................ 16 
............................................................ 17 

........................................................... 17 

.............................. 18 

.................................. 19 

............................... 20 

................................ 20 

............................................. 20 

................................................ 21 

DECLARATION OF INCORPORATION (FOR A PARTLY COMPLETED MACHINE) 

.............................. 22 

1.  SECURITY RULES 

 

C

AREFULLY  OBSERVE  ALL

PERSONAL SAFETY

.

 

I

MPROPER INSTALLATION

 

MANDATORY RISK ANALY

The  Nekos  electrical  actuators comply  with the  Machinery  Directive  (2006/42/EC), Standard 
IEC 60335-2-103 (Particular requirements for drives for gates, doors and windows) and other 
directives  and  regulations  indicated  in  the  attached  Declarations  of  Incor
Conformity  (at  the  end  of  the  manual).  According  to  the  Machinery  Directive,  actuators  are 
“partly  completed  machinery”  intended  for  incorporation  into  doors  and  windows.  The 
manufacturer/supplier  of  the  window  is  required,  with  exclusive  r
compliance  of the entire system  with  the  applicable standards  and  to issue CE  certification. 
We  strongly  discourage  any  use  of  the  actuators  other  than  that  specified  and  therefore,  in 
any case, the supplier of the complete sys
For  systems  installed  at  a  height  of  less  than  2.5  m  above  floor  level  or  other  levels 
accessible  to  users,  the  manufacturer/supplier  of  the  window  must  conduct 
regarding potential harm (violent blows, crushing, w
or possible malfunction or accidental breakage of the automated windows, and to implement 
suitable protective measures in view of these. Such measures include those recommended 
by the specified standard: 

-  controlling the actuators via a “deadman’s button” placed near the system and within the 

operator’s field of view, to ensure that people are out of the  way during operation. The 
button  must  be  placed  at  a  height  of  1,5  m  and  operated  by  key  if  accessible  to  the 
public; or:  

-  use  of  contact  safety  systems  (also  included  in  the  actuators)  that  ensure  a  maximum 

closing force of 400/150/25 N, measured in accordance with paragraph BB.20.107.2 of 
IEC 60335-2-103; or: 

-  use of non-contact safety systems (lasers, light grids); or:
-  use of fixed safety barriers that prevent access to moving parts.

Automated windows are deemed adequately protected if they: 

-  are installed at a height of >2.5 m; or:
-  have a leading-edge opening of <200 mm and a closing speed of <15 mm/s; or:
-  are part of a smoke and heat evacuation system for emergency use only.

In  any  case,  moving  parts  of  windows  that  could  fall  below  2.5  m  following  breakage  of  a 
system  component  need  to  be  fixed  or  secured  in  order  to  prevent  them  from  suddenly 
falling or collapsing: e.g. the use of safety arms on bottom

 

The  device  is  not  intended  for  use  by  persons  (including  children)  with  reduced 
physical,  sensory  or  mental  capabilities,  or  lacking  experience  and  knowledge.  Do 
not allow children to play  with the fixed 
out of their reach. 
The  actuator  is  destined  exclusively  for  installation  indoors.  For  any  special 
application we recommend you consult the manufacturer beforehand.
After removing packaging, check for any damage 
Always request exclusive use of original spare parts. Failure to respect this condition 
could compromise safety and invalidate the benefits contained in the warranty for the 
appliance. 
In  the  event  of  any  problems  or  queries,  consult  your
manufacturer directly. 

AREFULLY  OBSERVE  ALL  THE  FOLLOWING  INSTALLATION  INSTRUCTIONS 

MPROPER INSTALLATION CAN SERIOUSLY ENDANG

MANDATORY RISK ANALYSIS AND PROTECTION MEASURES

.

 

The  Nekos  electrical actuators comply  with the  Machinery Directive (2006/42/EC), Standard 

103 (Particular requirements for drives for gates, doors and windows) and other 

directives  and  regulations  indicated  in  the  attached  Declarations  of  Incor
Conformity  (at  the  end  of  the  manual).  According  to  the  Machinery  Directive,  actuators  are 
“partly  completed  machinery”  intended  for  incorporation  into  doors  and  windows.  The 
manufacturer/supplier  of  the  window  is  required,  with  exclusive  responsibility,  to  ensure  the 
compliance  of the  entire system  with  the  applicable  standards  and to issue  CE  certification. 
We  strongly  discourage  any  use  of  the  actuators  other  than  that  specified  and  therefore,  in 
any case, the supplier of the complete system retains full liability.  
For  systems  installed  at  a  height  of  less  than  2.5  m  above  floor  level  or  other  levels 
accessible  to  users,  the  manufacturer/supplier  of  the  window  must  conduct 
regarding potential harm (violent blows, crushing, wounds) caused to people by normal use 
or possible malfunction or accidental breakage of the automated windows, and to implement 

in view of these. Such measures include those recommended 

e actuators via a “deadman’s button” placed near the system and within the 

operator’s field of view, to ensure that people are out of the  way during operation. The 
button  must  be  placed  at  a  height  of  1,5  m  and  operated  by  key  if  accessible  to  the 

use  of  contact  safety  systems  (also  included  in  the  actuators)  that  ensure  a  maximum 
closing force of 400/150/25 N, measured in accordance with paragraph BB.20.107.2 of 

contact safety systems (lasers, light grids); or: 

use of fixed safety barriers that prevent access to moving parts. 

Automated windows are deemed adequately protected if they:  

are installed at a height of >2.5 m; or: 

edge opening of <200 mm and a closing speed of <15 mm/s; or:

smoke and heat evacuation system for emergency use only.

In  any  case,  moving  parts  of  windows  that  could  fall  below  2.5  m  following  breakage  of  a 
system  component  need  to  be  fixed  or  secured  in  order  to  prevent  them  from  suddenly 

g. the use of safety arms on bottom-hung windows.

The  device  is  not  intended  for  use  by  persons  (including  children)  with  reduced 
physical,  sensory  or  mental  capabilities,  or  lacking  experience  and  knowledge.  Do 
not allow children to play  with the fixed controls and keep any remote

The  actuator  is  destined  exclusively  for  installation  indoors.  For  any  special 
application we recommend you consult the manufacturer beforehand.
After removing packaging, check for any damage on the appliance.
Always request exclusive use of original spare parts. Failure to respect this condition 
could compromise safety and invalidate the benefits contained in the warranty for the 

In  the  event  of  any  problems  or  queries,  consult  your 

LATION  INSTRUCTIONS  TO  ENSURE 

CAN SERIOUSLY ENDANGER SAFETY

.

 

The  Nekos  electrical  actuators comply  with the  Machinery Directive (2006/42/EC), Standard 

103 (Particular requirements for drives for gates, doors and windows) and other 

directives  and  regulations  indicated  in  the  attached  Declarations  of  Incorporation  and  CE 
Conformity  (at  the  end  of  the  manual).  According  to  the  Machinery  Directive,  actuators  are 
“partly  completed  machinery”  intended  for  incorporation  into  doors  and  windows.  The 

esponsibility,  to  ensure  the 

compliance of the entire system  with  the  applicable  standards  and to issue  CE  certification. 
We  strongly  discourage  any  use  of  the  actuators  other  than  that  specified  and  therefore,  in 

For  systems  installed  at  a  height  of  less  than  2.5  m  above  floor  level  or  other  levels 
accessible  to  users,  the  manufacturer/supplier  of  the  window  must  conduct 

risk  analysis 

ounds) caused to people by normal use 

or possible malfunction or accidental breakage of the automated windows, and to implement 

in view of these. Such measures include those recommended 

e actuators via a “deadman’s button” placed near the system and within the 

operator’s field of view, to ensure that people are out of the  way during operation. The 
button  must  be  placed  at  a  height  of  1,5  m  and  operated  by  key  if  accessible  to  the 

use  of  contact  safety  systems  (also  included  in  the  actuators)  that  ensure  a  maximum 
closing force of 400/150/25 N, measured in accordance with paragraph BB.20.107.2 of 

edge opening of <200 mm and a closing speed of <15 mm/s; or: 

smoke and heat evacuation system for emergency use only. 

In  any  case,  moving  parts  of  windows  that  could  fall  below  2.5  m  following  breakage  of  a 
system  component  need  to  be  fixed  or  secured  in  order  to  prevent  them  from  suddenly 

hung windows. 

The  device  is  not  intended  for  use  by  persons  (including  children)  with  reduced 
physical,  sensory  or  mental  capabilities,  or  lacking  experience  and  knowledge.  Do 

controls and keep any remote-control units 

The  actuator  is  destined  exclusively  for  installation  indoors.  For  any  special 
application we recommend you consult the manufacturer beforehand. 

on the appliance. 

Always request exclusive use of original spare parts. Failure to respect this condition 
could compromise safety and invalidate the benefits contained in the warranty for the 

  agent  or  contact  the 

Summary of Contents for SKYRO 850

Page 1: ...ufacturer Do not use if repair or adjustment is required CAUTION if the power cable is damaged it must be replaced by qualified personnel from a service centre authorised by the manufacturer CAUTION D...

Page 2: ...or collapsing e g the use of safety arms on bottom The device is not intended for use by persons including children with reduced physical sensory or mental capabilities or lacking experience and knowl...

Page 3: ...tem in any case retaining sole liability The actuator is manufactured in accordance with the Directives and following Regulations listed in the attached Declaration of Incorporation and Conformity Ele...

Page 4: ...multiple Syncro actuators it is advisable to consider the force of each 90 of that stated on the plate ID PLATE AND MARKING DATA marking and comply with the Standards listed in the Declaration of Conf...

Page 5: ...pliers screwdrivers 10 Selection of power cable section The following table indicates maximum cable lengths for connection to a single motors Actuator fed at 24V 110V 20 m 300 m 30 m 450 m 40 m 600 m...

Page 6: ...and closure of the frame Make sure the frame closes fully and is weather tight K The limit switch for the actuator is automatic on re entry The equipment will exert a pressure to guarantee even the la...

Page 7: ...Syncro version motors in tandem 11 ELECTRICAL CONNECTIONS Appliances are equipped with cable manufactured in accordance with safety standards and protection against radio disturbances EACH ACTUATOR MO...

Page 8: ...eters including the distance The difference in height between the protruding part of the sash and the frame is known as and in the acquisition phase it allows the actuator to acquire the end parameter...

Page 9: ...ce will be saved and used With Syncro actuators they will move in sync and stop at RESET procedure lock is present refer to the respective user and installation outward rack travel of the actuator ful...

Page 10: ...upport brackets are aligned with one another and firmly secured to the window frame and that the screws are properly tightened The use inium windows is not recommended as they would tear the profile a...

Page 11: ...The person authorised to compile the relevant technical documentation is ing Matteo Stefani Nekos S r l Su richiesta adeguatamente motivata delle autorit nazionali la documentazione tecnica dei citat...

Page 12: ...23 24 NEKOS S r l Via Capitoni 7 5 36064 Colceresa VI ITALY 39 0424 411011 39 0424 411013 www nekos it info nekos it...

Reviews: