background image

11 

10.2.  Calculation of the number of push / retention points 

If the window has a width exceeding 120 cm, it is advisable to use several push / retention 
points by assembling several actuators. The simple formula below allows you to calculate 
the position of these points. 

Formula: 

The two side dimensions 

LA : (PA x 2) = QL 

The central dimensions

   - 

QL x 2

 

Legend: 

LA

 = Window Sash Width (hinges side) 

PA

 = Actuator Attachment Points 

QL

 = Side Dimensions 

Fig. 1 

Fig. 2 

Fig. 3 

Fig. 3 bis 

 

Fig. 4 

Fig. 5 

Fig. 5 bis 

Fig. 6 

10.3.  Assembly with outward opening window 

A.  Mark  the  centre  line  of  the  frame  in  pencil  on  both  moveable  and  fixed  parts  (Fig.  1). 

When more than one actuator is installed on the same window, mark as indicated in § 
10.2 above. 

B. 

Place the motor support bracket along the edge of the fixed part of the frame in line 
with the centre line marked out previously and mark the positions for the four holes 
for the fixing screws 

(Fig. 2). 

C. Drill holes into the frame and screw in the motor support bracket, making sure that all 

screws are fitted tightly (Fig. 3 and Fig. 3bis). 

D. Line  up the front  bracket  along the  centre line  on the moveable  part  of the frame  and 

mark out the holes required for the screws (Fig. 4). 

E. 

Drill the holes and screw in the front bracket, making sure that all screws are fitted 
tightly 

(Fig.5 and Fig. 5bis). 

F.  Take  the  clamp  screws  and  connect  them  to  the  motor  support  bracket.  Leave  them 

slack by at least two turns. 

G. 

Insert the dove-tailed section of the actuator into the clamp screws. Make sure the 
shaped part of the base fits neatly into the slot to ensure the actuator runs smoothly 
along its axis 

(Fig. 6). 

H. 

Now  position  the  actuator  so  the  eyebolt  head  is  inserted  into  the  front  bracket 
support. Insert the M6x25 screw into the bracket and into the eyebolt and tighten the 
self-locking bolt with two 10 spanners.

 

12 

I.  Manually  move  the  actuator  along  its  axis  to  close  the  frame  and  make  it  weather 

tight.  Tighten  the  clamp  screws previously  only  placed  and  set  the  actuator  in  line 
with the frame. Suggested tightening torque is 4-5 Nm. 

J. 

Plug the actuator in and carry out a test to check opening and closure of the frame. 
Make sure the frame closes fully and is weather tight. 

 

K. 

The limit switch for the actuator is automatic on re-entry. The equipment will exert a 
pressure to guarantee even the largest of frames is completely weather tight.

 

10.4.  Installation on domed rooflights, dormers or industrial skylights   

To  install  the  actuator  on  these  types  of  windows,  follow  the  instructions  for  “Installation  on 
awning windows” given in § 10.3 above. 

10.5.  Assembly with opening inwards 

A. 

Mark  the  centre  line  of  the  frame  in  pencil  on  both  moveable  and  fixed  parts 

(Fig.1). 

When more than one actuator is installed on the same window, mark as indicated in § 10.2 
above. 

B. 

Place the motor support bracket along the edge of the moveable part of the frame in 
line  with  the  centre  line  marked  out  previously  and  mark  the  positions for  the  four 
holes for the fixing screws 

(Fig. 2). 

C. 

Drill holes into the frame and screw in the motor support bracket, making sure that 
all screws are fitted tightly 

(Fig. 3 and Fig. 3bis). 

D. 

Line  up  the  front  bracket  along  the  centre  line  on  the  fixed  part  of  the  frame  and 
mark out the holes required for the screws 

(Fig. 4). 

E. 

Drill the holes and screw in the front bracket, making sure that all screws are fitted 
tightly 

(Fig. 5 and Fig. 5bis). 

F. 

Take  the  clamp  screws  and  connect  them  to  the  motor  support  bracket.  Leave  them 
slack by at least two turns.

 

G. Insert the dove-tailed section of the actuator into the clamp screws. Make sure the 

shaped part of the base fits neatly into the slot to ensure the actuator runs smoothly 
along its axis 

(Fig. 6).

 

H. Now  position  the  actuator  so  the  eyebolt  head  is  inserted  into  the  front  bracket 

support. Insert the M6x25 screw into the bracket and into the eyebolt and tighten the 
self-locking bolt with two 10 spanners. 

I.  Manually  move  the  actuator  along  its  axis  to  close  the  frame  and  make  it  weather 

tight.  Tighten  the  clamp  screws previously  only  placed  and  set  the  actuator  in  line 
with the frame. Suggested tightening torque is 4-5 Nm. 

J.  Perform  a  complete  opening  and  closing  test  on  the  window.  When  the  closing 

operation  is  completed,  ensure  that  the  window  is  properly  closed  by  checking  the 
compression of the seals. 

K.  The stroke-end of the actuator during return is automatic. The device exerts traction to 

ensure perfect compression of the seals. 

Summary of Contents for SKYRO 850

Page 1: ...ufacturer Do not use if repair or adjustment is required CAUTION if the power cable is damaged it must be replaced by qualified personnel from a service centre authorised by the manufacturer CAUTION D...

Page 2: ...or collapsing e g the use of safety arms on bottom The device is not intended for use by persons including children with reduced physical sensory or mental capabilities or lacking experience and knowl...

Page 3: ...tem in any case retaining sole liability The actuator is manufactured in accordance with the Directives and following Regulations listed in the attached Declaration of Incorporation and Conformity Ele...

Page 4: ...multiple Syncro actuators it is advisable to consider the force of each 90 of that stated on the plate ID PLATE AND MARKING DATA marking and comply with the Standards listed in the Declaration of Conf...

Page 5: ...pliers screwdrivers 10 Selection of power cable section The following table indicates maximum cable lengths for connection to a single motors Actuator fed at 24V 110V 20 m 300 m 30 m 450 m 40 m 600 m...

Page 6: ...and closure of the frame Make sure the frame closes fully and is weather tight K The limit switch for the actuator is automatic on re entry The equipment will exert a pressure to guarantee even the la...

Page 7: ...Syncro version motors in tandem 11 ELECTRICAL CONNECTIONS Appliances are equipped with cable manufactured in accordance with safety standards and protection against radio disturbances EACH ACTUATOR MO...

Page 8: ...eters including the distance The difference in height between the protruding part of the sash and the frame is known as and in the acquisition phase it allows the actuator to acquire the end parameter...

Page 9: ...ce will be saved and used With Syncro actuators they will move in sync and stop at RESET procedure lock is present refer to the respective user and installation outward rack travel of the actuator ful...

Page 10: ...upport brackets are aligned with one another and firmly secured to the window frame and that the screws are properly tightened The use inium windows is not recommended as they would tear the profile a...

Page 11: ...The person authorised to compile the relevant technical documentation is ing Matteo Stefani Nekos S r l Su richiesta adeguatamente motivata delle autorit nazionali la documentazione tecnica dei citat...

Page 12: ...23 24 NEKOS S r l Via Capitoni 7 5 36064 Colceresa VI ITALY 39 0424 411011 39 0424 411013 www nekos it info nekos it...

Reviews: