background image

4420148 - Rev 1 del 03/2021 

 

 
 
 

SKYRO 850 

 
 

INSTRUCTION MANUAL - 

TRANSLATION OF ORIGINAL INSTRUCTIONS 

RACK ACTUATOR 

Force 850N – Strokes 350, 550, 750, 1000 mm 
Electrical feeding 110-230V~ 50/60Hz and 24V

 

 
 
 
 
 

 

 
 
 
 

 
 

 

NEKOS

 S.r.l. - Via Capitoni, 7/5 - 

36064 Colceresa – VI – ITALY 

  

 +39 0424 411011 – 

 +39 0424 411013 - www.nekos.it - [email protected] 

EN 

 

 

 

USER INSTRUCTIONS 

 

 
 

CAUTION.  Carefully  observe  all  the  following  installation 
instructions to ensure personal safety.  
 
The  device  is  not  intended  for  use  by  persons  (including  children) 
with  reduced  physical,  sensory  or  mental  capabilities,  or  lacking 
experience  and  knowledge.  Do  not  allow  children  to  play  with  the 
fixed controls and keep any remote-control units out of their reach. 
 
Have  installation  checks  performed  periodically  by  qualified 
personnel from a service centre authorised by the manufacturer. Do 
not use if repair or adjustment is required.  
 
CAUTION:  if  the  power  cable  is  damaged,  it  must  be  replaced  by 
qualified  personnel  from  a  service  centre  authorised  by  the 
manufacturer. 
 
CAUTION.  Disconnect  the  power  supply  during  cleaning  or 
maintenance  operations.  Do  not  use  solvents  or  jets  of  water  to 
wash  the  appliance;  the  appliance  should  not  be  submerged  in 
water. 
 
In the event of fault or malfunction, switch off the device at the main 
switch.  All  repairs  and  adjustments  (e.g.  setting  the  stroke)  must 
only  be  performed  by  qualified  personnel  from  a  service  centre 
authorised by the manufacturer.  
 
Always  request  exclusive  use  of  original  spare  parts.  Failure  to 
respect  this  condition  could  compromise  safety  and  invalidate  the 
benefits contained in the warranty for the appliance. In the event of 
any  problems  or  queries,  consult  your  agent  or  contact  the 
manufacturer directly. 
 
The A-weighted sound pressure level is less than 70dB(A). 
 
Carefully preserve these instructions after installation. 
 

Summary of Contents for SKYRO 850

Page 1: ...ufacturer Do not use if repair or adjustment is required CAUTION if the power cable is damaged it must be replaced by qualified personnel from a service centre authorised by the manufacturer CAUTION D...

Page 2: ...or collapsing e g the use of safety arms on bottom The device is not intended for use by persons including children with reduced physical sensory or mental capabilities or lacking experience and knowl...

Page 3: ...tem in any case retaining sole liability The actuator is manufactured in accordance with the Directives and following Regulations listed in the attached Declaration of Incorporation and Conformity Ele...

Page 4: ...multiple Syncro actuators it is advisable to consider the force of each 90 of that stated on the plate ID PLATE AND MARKING DATA marking and comply with the Standards listed in the Declaration of Conf...

Page 5: ...pliers screwdrivers 10 Selection of power cable section The following table indicates maximum cable lengths for connection to a single motors Actuator fed at 24V 110V 20 m 300 m 30 m 450 m 40 m 600 m...

Page 6: ...and closure of the frame Make sure the frame closes fully and is weather tight K The limit switch for the actuator is automatic on re entry The equipment will exert a pressure to guarantee even the la...

Page 7: ...Syncro version motors in tandem 11 ELECTRICAL CONNECTIONS Appliances are equipped with cable manufactured in accordance with safety standards and protection against radio disturbances EACH ACTUATOR MO...

Page 8: ...eters including the distance The difference in height between the protruding part of the sash and the frame is known as and in the acquisition phase it allows the actuator to acquire the end parameter...

Page 9: ...ce will be saved and used With Syncro actuators they will move in sync and stop at RESET procedure lock is present refer to the respective user and installation outward rack travel of the actuator ful...

Page 10: ...upport brackets are aligned with one another and firmly secured to the window frame and that the screws are properly tightened The use inium windows is not recommended as they would tear the profile a...

Page 11: ...The person authorised to compile the relevant technical documentation is ing Matteo Stefani Nekos S r l Su richiesta adeguatamente motivata delle autorit nazionali la documentazione tecnica dei citat...

Page 12: ...23 24 NEKOS S r l Via Capitoni 7 5 36064 Colceresa VI ITALY 39 0424 411011 39 0424 411013 www nekos it info nekos it...

Reviews: