Force 600N – Strokes 180, 230, 350, 550, 750, 1000 mm 
Electrical feeding 110-230V~ 50/60Hz and 24V

 

 
 
 

 

 

 
 
 
 
 

NEKOS

 S.r.l. - Via Capitoni, 7/5 - 

36064 Colceresa – VI – ITALY 

  

 +39 0424 411011 – 

 +39 0424 411013 - www.nekos.it - [email protected] 

 

EN 

 
 

 

USER INSTRUCTIONS 

 

 
 

CAUTION.  Carefully  observe  all  the  following  installation 
instructions to ensure personal safety.  
 
The  device  is  not  intended  for  use  by  persons  (including  children) 
with  reduced  physical,  sensory  or  mental  capabilities,  or  lacking 
experience  and  knowledge.  Do  not  allow  children  to  play  with  the 
fixed controls and keep any remote-control units out of their reach. 
 
Have  installation  checks  performed  periodically  by  qualified 
personnel from a service centre authorised by the manufacturer. Do 
not use if repair or adjustment is required.  
 
CAUTION:  if  the  power  cable  is  damaged,  it  must  be  replaced  by 
qualified  personnel  from  a  service  centre  authorised  by  the 
manufacturer. 
 
CAUTION.  Disconnect  the  power  supply  during  cleaning  or 
maintenance  operations.  Do  not  use  solvents  or  jets  of  water  to 
wash  the  appliance;  the  appliance  should  not  be  submerged  in 
water. 
 
In the event of fault or malfunction, switch off the device at the main 
switch.  All  repairs  and  adjustments  (e.g.  setting  the  stroke)  must 
only  be  performed  by  qualified  personnel  from  a  service  centre 
authorised by the manufacturer.  
 
Always  request  exclusive  use  of  original  spare  parts.  Failure  to 
respect  this  condition  could  compromise  safety  and  invalidate  the 
benefits contained in the warranty for the appliance. In the event of 
any  problems  or  queries,  consult  your  agent  or  contact  the 
manufacturer directly. 
 
The A-weighted sound pressure level is less than 70dB(A). 
 
Carefully preserve these instructions after installation. 

 
 

Summary of Contents for SKY 650

Page 1: ...if repair or adjustment is required CAUTION if the power cable is damaged it must be replaced by qualified personnel from a service centre authorised by the manufacturer CAUTION Disconnect the power...

Page 2: ...ndards and to issue CE certification We strongly discourage any use of the actuators other than that specified and therefore in any case the supplier of the complete system retains full liability For...

Page 3: ...this reason no adjustment is required 4 Construction and standards INTENDED USE The SKY650 rack actuator has been designed and manufactured to open and close top hung windows opening outwards bottom h...

Page 4: ...00 mmq 40 m 600 m 2800 m 1 50 mmq 60 m 900 m 4000 m 2 50 mmq 100 m 1500 m 6800 m 4 00 mmq 160 m 2500 m 11000 m 6 00 mmq 240m 3700 m 15000 m 8 8 Instructions for assembly These indications are intende...

Page 5: ...d out previously and mark the positions for the four holes for the fixing screws Fig 2 C Drill holes into the frame and screw in the motor support bracket making sure that all screws are fitted tightl...

Page 6: ...wires marked black and brown for 110 230V motors WARNING after every limit switch or electronic protection device function the rack will back track for around 2 mm in the opposite direction This is qu...

Page 7: ...ging etc be sent to a centre for ecological recycling as established from laws in force on recycling The device is mainly made from the following materials aluminium zinc iron plastic of various type...

Page 8: ...iva Compatibilit Elettromagnetica ElectroMagnetic Compatibility Directive EMCD 2014 35 EU Direttiva Bassa Tensione Low Voltage Directive LVD 2011 65 EU Direttiva sulla restrizione dell uso di determin...

Reviews: