INSTALLER INSTRUCTIONS 

 

 
 

nekos

 products have been manufactured in accordance with safety standards and conforms to the 

stipulations of current standards in force.  
When correctly assembled, installed and used according to the present instructions, they will not 
generate any danger for persons, animals or items.  
 
 

Symbols used in the manual 

 

 

DANGER 

This indication draw the attention about potential dangers for safety and 
health of peoples and animals. 

 

Contents 

1.  Security rules .................................................................................................................. 4 
2.  Formulas and recommendations for installation  .............................................................. 5 

2.1. Calculation of opening / closure force ........................................................................ 5 
2.2. Maximum opening in accordance with sash height .................................................... 5 

3.  Technical information about function ............................................................................... 5 
4.  Construction and standards ............................................................................................ 6 
5.  Id plate and marking data ............................................................................................... 6 
6.  Technical specifications .................................................................................................. 7 
7.  Electrical supply .............................................................................................................. 7 

7.1. Section choice of supply cables ................................................................................ 7 

8.  Instructions for assembly ................................................................................................ 8 

8.1. Preparation of actuator for assembly ......................................................................... 8 
8.2. Assembly with outward opening window ................................................................... 9 
8.3. Assembly for cupolas or dormer windows ................................................................. 9 
8.4. Assembly for transom windows ................................................................................. 9 
8.5. Assembly of more than one actuator with connection bar ........................................ 10 

9.  Electrical connections ................................................................................................... 11 
10. Limit switches ............................................................................................................... 12 

10.1.  Stroke-end at opening and closure ...................................................................... 12 
10.2.  Stroke adjustment where required ....................................................................... 12 

11. Checking for correct assembly ...................................................................................... 12 
12. Emergency manoeuvres, maintenance and cleaning ..................................................... 13 
13. Troubleshooting ............................................................................................................ 13 
14. Environmental protection .............................................................................................. 13 
15. Certificate of guarantee ................................................................................................. 13 
16. Declaration of incorporation (for a partly completed machine) and EC Declaration of 

Conformity .................................................................................................................... 15 

 

 
 

1.  Security rules 

 

C

AREFULLY  OBSERVE  ALL  THE  FOLLOWING  INSTALLATION  INSTRUCTIONS  TO  ENSURE 

PERSONAL SAFETY

.

 

I

MPROPER INSTALLATION CAN SERIOUSLY ENDANGER SAFETY

.

 

 

 

MANDATORY RISK ANALYSIS AND PROTECTION MEASURES

The Nekos  electrical  actuators comply  with the Machinery Directive  (2006/42/EC),  Standard 
IEC 60335-2-103 (Particular requirements for drives for gates, doors and windows) and other 
directives  and  regulations  indicated  in  the  attached  Declarations  of  Incorporation  and  CE 
Conformity  (at  the  end  of  the  manual).  According  to  the  Machinery  Directive,  actuators  are 
“partly  completed  machinery”  intended  for  incorporation  into  doors  and  windows.  The 
manufacturer/supplier  of  the  window  is  required,  with  exclusive  responsibility,  to  ensure  the 
compliance  of the entire  system  with  the  applicable  standards  and to issue  CE  certification. 
We  strongly  discourage  any  use  of  the  actuators  other  than  that  specified  and  therefore,  in 
any case, the supplier of the complete system retains full liability.  
For  systems  installed  at  a  height  of  less  than  2.5  m  above  floor  level  or  other  levels 
accessible  to  users,  the  manufacturer/supplier  of  the  window  must  conduct 

risk  analysis 

regarding potential harm (violent blows, crushing, wounds) caused to people by normal use 
or possible malfunction or accidental breakage of the automated windows, and to implement 
suitable protective measures in view of these. Such measures include those recommended 
by the specified standard: 

-  controlling the actuators via a “deadman’s button” placed near the system and within the 

operator’s field of view, to ensure that people are out of the way during operation. The 
button  must  be  placed  at  a  height  of  1.5  m  and  operated  by  key  if  accessible  to  the 
public; or:  

-  use  of  contact  safety  systems  (also  included  in  the  actuators)  that  ensure  a  maximum 

closing force of 400/150/25 N, measured in accordance with paragraph BB.20.107.2 of 
IEC 60335-2-103; or: 

-  use of non-contact safety systems (lasers, light grids); or: 
-  use of fixed safety barriers that prevent access to moving parts. 

Automated windows are deemed adequately protected if they:  
- are installed at a height of >2.5 m; or: 

 - have a leading-edge opening of <200 mm and a closing speed of <15 mm/s; or: 

- are part of a smoke and heat evacuation system for emergency use only. 
In  any  case,  moving  parts  of  windows  that  could  fall  below  2.5  m  following  breakage  of  a 
system  component  need  to  be  fixed  or  secured  in  order  to  prevent  them  from  suddenly 
falling or collapsing: e.g. the use of safety arms on bottom-hung windows. 

 

The  device  is  not  intended  for  use  by  persons  (including  children)  with  reduced 
physical,  sensory  or  mental  capabilities,  or  lacking  experience  and  knowledge.  Do 
not allow children to play with the fixed controls and keep any remote-control units 
out of their reach. 
The  actuator  is  destined  exclusively  for  installation  indoors.  For  any  special 
application we recommend you consult the manufacturer beforehand. 
After removing packaging, check for any damage on the appliance. 
Always request exclusive use of original spare parts. Failure to respect this condition 
could  compromise  safety  and  invalidate  the  benefits  contained  in  the  warranty  for 
the appliance. 
In  the  event  of  any  problems  or  queries,  consult  your  agent  or  contact  the 
manufacturer directly. 

Summary of Contents for SKY 650

Page 1: ...if repair or adjustment is required CAUTION if the power cable is damaged it must be replaced by qualified personnel from a service centre authorised by the manufacturer CAUTION Disconnect the power...

Page 2: ...ndards and to issue CE certification We strongly discourage any use of the actuators other than that specified and therefore in any case the supplier of the complete system retains full liability For...

Page 3: ...this reason no adjustment is required 4 Construction and standards INTENDED USE The SKY650 rack actuator has been designed and manufactured to open and close top hung windows opening outwards bottom h...

Page 4: ...00 mmq 40 m 600 m 2800 m 1 50 mmq 60 m 900 m 4000 m 2 50 mmq 100 m 1500 m 6800 m 4 00 mmq 160 m 2500 m 11000 m 6 00 mmq 240m 3700 m 15000 m 8 8 Instructions for assembly These indications are intende...

Page 5: ...d out previously and mark the positions for the four holes for the fixing screws Fig 2 C Drill holes into the frame and screw in the motor support bracket making sure that all screws are fitted tightl...

Page 6: ...wires marked black and brown for 110 230V motors WARNING after every limit switch or electronic protection device function the rack will back track for around 2 mm in the opposite direction This is qu...

Page 7: ...ging etc be sent to a centre for ecological recycling as established from laws in force on recycling The device is mainly made from the following materials aluminium zinc iron plastic of various type...

Page 8: ...iva Compatibilit Elettromagnetica ElectroMagnetic Compatibility Directive EMCD 2014 35 EU Direttiva Bassa Tensione Low Voltage Directive LVD 2011 65 EU Direttiva sulla restrizione dell uso di determin...