background image

The plate data is displayed on an  adhesive label placed on the  outside  of the casing, 
which must remain intact and visible.  
The  main  information  it  displays  includes:  manufacturer's  address,  product  name  - 
model  number,  technical  characteristics,  production  date  and  serial  number.  In  the 
event of a complaint, please indicate the serial number (SN) displayed on the label. 
An  explanation  of  the  symbols  used  on  the  label  to  abbreviate  the  technical 
characteristics is given in the table in the chapter on “TECHNICAL DATA”. 

6.  Construction and standards 

 

INTENDED  USE.

  The  SKY450  rack  actuator  has  been  designed  and 

manufactured to  open and close top hung windows opening outwards, bottom 
hung windows, dormer windows, light domes and skylights. Specific use is for 
ventilation and airing of areas; any other use is strongly discouraged, with the 
supplier of the entire system in any case retaining sole liability. 
The  actuator  is  manufactured  in  accordance  with  the  Directives  and  following 
Regulations listed in the attached Declaration of Incorporation and Conformity 

Electrical connections must  conform  to regulations  in force  for the  design  and 
set up of electrical equipment. 
To ensure efficient separation from the grid, an approved type of bipolar “dead-man” 
switch should be used. An omnipolar general power switch with minimum distance 
of 3 mm between contacts should be installed upstream of the control line. 
Application  is  performed  using  the  brackets  provided  and  any  other  type  of 
assembly  should  be  checked  with  the  manufacturer,  who  will  not  accept  any 
responsibility for incorrect or malfunctioning assembly. 

The  actuator  comes  packaged  in  a  cardboard  container  which  contains  two  pieces. 
Each package contains: 

  Nr. 2  110-230V~ 50/60Hz electrical actuators 

  Nr. 2  Standard support brackets with respective grips and fixing screws. 

 

(Grips and fixing screws are inside small part packaging).

 

  Nr. 2  Brackets for fixing to the frame. 

  Nr. 2  Small part packaging. 

  Nr. 1  Instruction manual.

 

7. 

Electrical power supply 

SKY450 is commercially available in one single version: 

 

SKY450 230V

: runs on grid tension of 110-230V~ 50/60Hz, with a three wire cable 

(

L

IGHT 

B

LUE

, common neutral; 

B

LACK

, phase open; 

B

ROWN

, phase closed).

 

 

 

 

8. 

Instructions for assembly 

These indications are for specialised technical personnel and basic work and 

safety techniques are not indicated. 

All  preparatory,  assembly  and  electrical  connection  operations  must  be  performed  by 
specialised  technical  personnel  to  guarantee  optimal  function  and  service  of  the 
actuator. Check that the following fundamental conditions have been met: 

 

Before  installing  the  actuator,  check  that  the  moving  parts  of  the  window  on 
which  it  is  to  be  installed  are  in  perfect  working  condition  and  that  they  open 
and close properly and are well balanced (where applicable).  
Gear  motor  performances  must  be  sufficient  to  move  the  window;  any  limits 
indicated in the technical data table on the product cannot be exceeded (page 
6). Any eventual calculations may be made using the formula on page 5 of this 
manual. 

Warning

:  Check  that  appliance  has  electrical  feeding  type  equal  to  the  one 

provided by checking with the data reported  on  the label attached to the gear 
motor. 
Check  that  the  actuator  has  not  been  damaged  during  transport,  first  visually 
and then by working it in both directions. 
Transom window frames entail the risk of injury caused by accidental fall of the 
window. A compass limit switch or alternative safety system suitably designed 
to prevent any accidental falls should be installed. 

8.1.  Preparation of actuator for assembly 

Before starting assembly of the actuator, prepare the following material for completion, 
equipments and tools.  

 

For  fixing  onto  metal  window  frames:  M5  threaded  inserts 

(6  pieces)

,  M5x12  flat 

headed metric screws 

(6 pieces)

 

For  fixing  onto  wooden  window  frames:  self  threading  screws  for  wood  Ø4.5 

(6 

pieces)

 

For  fixing  onto  PVC  window  frames:  self  threading  screws  for  metal  Ø4.8 

(6 

pieces)

 

Equipment and tools: measuring tape, pencil, drill/screwdriver, set of drill heads for 
metal, insert for screwing in, electricians pliers, screwdrivers. 

8.2.  Assembly for top hung windows opening outwards 

A.  Pencil  in  the  middle  line  for  the  window  frame  on  both 

mobile and fixed parts (Fig. 1). 

B.  Place  the  motor  support  bracket  in  position  at  the  edge  of 

the  fixed  part  in  line  with  the  centre  line  pencilled  in  earlier 
and pencil in the four openings to be used for fixing (Fig. 2). 

C. Use  the  appropriate  drill  head  to  perforate  the  window 

frame  and  assemble  the  motor  support  bracket,  taking 
care to tighten all screws well (Fig. 3 and Fig. 3bis). 

 

 

Fig. 1 

Summary of Contents for SKY 450

Page 1: ...if repair or adjustment is required CAUTION if the power cable is damaged it must be replaced by qualified personnel from a service centre authorised by the manufacturer CAUTION Disconnect the power s...

Page 2: ...lity to ensure the compliance of the entire system with the applicable standards and to issue CE certification We strongly discourage any use of the actuators other than that specified and therefore i...

Page 3: ...roke for the window CANNOT be programmed as it is regulated by the length of the rod on the reduction motor The electronic control device allows the rack to protrude until it encounters an obstacle th...

Page 4: ...closed 8 8 Instructions for assembly These indications are for specialised technical personnel and basic work and safety techniques are not indicated All preparatory assembly and electrical connection...

Page 5: ...e of drill head for perforation and assemble the front bracket taking care to fix the screws securely into position Fig 5 and Fig 5bis F Take the clamp screws and assemble them onto the motor support...

Page 6: ...the clamp screws slightly into the profile and lightly fix the screws into position Check the rack is aligned with that of the motorised actuator G Loosen the clamp screws and place the eyebolt heads...

Page 7: ...ts 1 and 2 in reverse order In the event in which the cable of feeding it is damaged to make to replace it from the constructor or a qualified technician 13 Environmental protection All materials used...

Page 8: ...otti sono conformi alle disposizioni pertinenti delle seguenti Direttive Furthermore the products listed above complies with the provisions of followings Directives 2014 30 EU Direttiva Compatibilit E...