3
INSTALLER INSTRUCTIONS
nekos
products have been manufactured in accordance with safety standards and conforms to the
stipulations of current standards in force.
When correctly assembled, installed and used according to the present instructions, they will not
generate any danger for persons, animals or items.
Symbols used in the manual
DANGER
This indication draw the attention about potential dangers for safety and
health of peoples and animals.
Contents
1. Safety indications ....................................................................................................... 4
2. Formulas and recommendations for installation ....................................................... 5
2.1. Calculation of opening / closure force................................................................ 5
2.2. Maximum opening in accordance with sash height ........................................... 5
3. Technical information about function ......................................................................... 6
4. Technical data ............................................................................................................ 6
5. Id plate and marking data .......................................................................................... 6
6. Construction and standards ....................................................................................... 7
7. Electrical power supply .............................................................................................. 7
8. Instructions for assembly ........................................................................................... 8
8.1. Preparation of actuator for assembly .................................................................... 8
8.2. Assembly for top hung windows opening outwards ............................................. 8
8.3. Assembly on light domes or dormer windows ...................................................... 9
8.4. Assembly with bottom hung windows ................................................................... 9
8.5. Assembly on louvre windows without mechanical lock or on sunshades ............. 10
8.6. Assembly in tandem with connection bar ........................................................... 11
9. Electrical connections .............................................................................................. 12
10. Stroke-end................................................................................................................ 12
10.1. Stroke-end at opening and closure ..................................................................... 12
10.2. Stroke adjustment where required ...................................................................... 12
11. Checking for correct assembly ................................................................................. 13
12. Emergency manoeuvres, maintenance and cleaning .............................................. 13
13. Environmental protection ......................................................................................... 13
14. Certificate of guarantee ............................................................................................ 14
15. Declaration of conformity ......................................................................................... 15
4
1. Security rules
C
AREFULLY OBSERVE ALL THE FOLLOWING INSTALLATION INSTRUCTIONS TO
ENSURE PERSONAL SAFETY
.
I
MPROPER INSTALLATION CAN SERIOUSLY ENDANGER
SAFETY
.
MANDATORY RISK ANALYSIS AND PROTECTION MEASURES
.
The Nekos electrical actuators comply with the Machinery Directive (2006/42/EC),
Standard IEC 60335-2-103 (Particular requirements for drives for gates, doors and
windows) and other directives and regulations indicated in the attached Declarations of
Incorporation and CE Conformity (at the end of the manual). According to the Machinery
Directive, actuators are “partly completed machinery” intended for incorporation into doors
and windows. The manufacturer/supplier of the window is required, with exclusive
responsibility, to ensure the compliance of the entire system with the applicable standards
and to issue CE certification. We strongly discourage any use of the actuators other than
that specified and therefore, in any case, the supplier of the complete system retains full
liability.
For systems installed at a height of less than 2.5 m above floor level or other levels
accessible to users, the manufacturer/supplier of the window must conduct
risk analysis
regarding potential harm (violent blows, crushing, wounds) caused to people by normal
use or possible malfunction or accidental breakage of the automated windows, and to
implement suitable protective measures in view of these. Such measures include those
recommended by the specified standard:
- controlling the actuators via a “deadman’s button” placed near the system and within
the operator’s field of view, to ensure that people are out of the way during operation.
The button must be placed at a height of 1.5 m and operated by key if accessible to
the public; or:
- use of contact safety systems (also included in the actuators) that ensure a maximum
closing force of 400/150/25 N, measured in accordance with paragraph BB.20.107.2
of IEC 60335-2-103; or:
- use of non-contact safety systems (lasers, light grids); or:
- use of fixed safety barriers that prevent access to moving parts.
Automated windows are deemed adequately protected if they:
- are installed at a height of >2.5 m; or:
- have a leading-edge opening of <200 mm and a closing speed of <15 mm/s; or:
- are part of a smoke and heat evacuation system for emergency use only.
In any case, moving parts of windows that could fall below 2.5 m following breakage of a
system component need to be fixed or secured in order to prevent them from suddenly
falling or collapsing: e.g. the use of safety arms on bottom-hung windows.
The device is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lacking experience and knowledge.
Do not allow children to play with the fixed controls and keep any remote-control
units out of their reach.
The actuator is destined exclusively for installation indoors. For any special
application we recommend you consult the manufacturer beforehand.
After removing packaging, check for any damage on the appliance.
Always request exclusive use of original spare parts. Failure to respect this