Page 17
Advanced procedure: associate desired channels or free a channel (“chc” menu).
- Select the “
CHC
” item in the menu of the station.
- Press the “
OK
” button of the control unit.
- The message “
Push
” will appear on the display.
- Select the desired channel on the PIK radio remote control and press any one of
the ▲/▼ ARROW or STOP buttons for about 1 second.
- The list of actuators from MOT1 to MOT6 and NULL will appear on the display.
If you want to “free” a certain channel of the PIK (e.g., make it usable for other
applications), select “
NULL
”.
- Use the +/- buttons of the control unit to scroll through the exits and select the one
you want to be associated with the selected channel.
- Press
OK
.
If CH1 is associated to exit 2, exit 1 can not be commanded from the remote control. To
associate CH2 to exit 1 it’s necessary to repeat the advanced procedure choosing CH2
with exit 1. The procedure is repeated for possible other remote controls or channels.
6.5.
Saving a radio remote control without access to the board
Saving a new radio remote control remotely, i.e. without access to the electronic board
of the station, can occur only if the user already has a previously saved radio remote
control.
Obtain the instructions manual of the PIK radio remote control for consultation.
The programming is achieved by carrying out the following procedure:
Equip yourself with the PIK radio remote control to be saved and set it on any
channel
(see the instructions of the radio remote control)
.
Equip yourself with the already saved and operational radio remote control, press
the following buttons in sequence:
F1
,
F2
and then
STOP
.
Within 5 seconds, on the radio remote control to be saved, press one of the ▲ arrow,
STOP
or ▼ arrow buttons twice.
Now the second radio remote control is operational.
Page 18
7. OVERALL DIMENSIONS
The container box is made of impact-resistant ABS engineering plastic, RAL7035 grey
colored, having a cover with gasket and IP65 degree of protection.
The feed-through holes for the cables, both those for the electric power supply and those
coming from the sensors, as well as those going to the actuators to be controlled, are
not present on the box. The holes must be made by the installer as needed.
During the drilling of the holes, be very careful so as not to damage the
electronic board.
Dimension
A
B
C
D
E
240
190
120
220
152