Advanced procedure: associate desired channels or free a channel (“chc” menu). 

-  Select the “

CHC

” item in the menu of the station. 

-  Press the “

OK

” button of the control unit. 

-  The message “

Push

” will appear on the display. 

-  Select the desired channel on the PIK radio remote control and press any one of 

the ▲/▼ ARROW or STOP buttons for about 1 second. 

-  The list of actuators from MOT1 to MOT6 and NULL will appear on the display. 

If you want to “free” a certain channel of the PIK (e.g., make it usable for other 
applications), select “

NULL

”. 

-  Use the +/- buttons of the control unit to scroll through the exits and select the one 

you want to be associated with the selected channel.  

-  Press 

OK

If CH1 is associated to exit 2, exit 1 can not be commanded from the remote control. To 
associate CH2 to exit 1 it’s necessary to repeat the advanced procedure choosing CH2 
with exit 1. The procedure is repeated for possible other remote controls or channels. 

6.5. 

Saving a radio remote control without access to the board 

Saving a new radio remote control remotely, i.e. without access to the electronic board 
of the station, can occur only if the user already has a previously saved radio remote 
control. 

 

Obtain the instructions manual of the PIK radio remote control for consultation. 

 

The programming is achieved by carrying out the following procedure: 

  Equip  yourself  with  the  PIK  radio  remote  control  to  be  saved  and  set  it  on  any 

channel 

(see the instructions of the radio remote control)

  Equip yourself with the already saved and operational radio remote control, press 

the following buttons in sequence: 

F1

F2

 and then 

STOP

  Within 5 seconds, on the radio remote control to be saved, press one of the ▲ arrow, 

STOP

 or ▼ arrow buttons twice.  

  Now the second radio remote control is operational. 

 

 

 

 

 

 

Page 18 

7.  OVERALL DIMENSIONS  

The container box is made of impact-resistant ABS engineering plastic, RAL7035 grey 
colored, having a cover with gasket and IP65 degree of protection.  
The feed-through holes for the cables, both those for the electric power supply and those 
coming from the sensors, as well as those going to the actuators to be controlled, are 
not present on the box. The holes must be made by the installer as needed.    
 

 

 

During  the  drilling  of  the  holes,  be  very  careful  so  as  not  to  damage  the 
electronic board. 

 

 

 

 

Dimension 

240 

190 

120 

220 

152 

 

 

 

Summary of Contents for KL

Page 1: ...eriodically by qualified personnel from a service centre authorised by the manufacturer Do not use if repair or adjustment is required CAUTION Disconnect the power supply during cleaning or maintenanc...

Page 2: ...acturer after technical review of the assembly The device is not intended for use by persons including children with reduced physical sensory or mental capabilities or lacking experience and knowledge...

Page 3: ...warnings below Perform a thorough visual inspection of the device to ensure it wasn t damaged during transport To avoid the hazard of injury or death caused by the electrical current always disconnec...

Page 4: ...system A display is installed on the station whit a programming menu for all the station functions All the settings of the PXXX functional parameters must be made through the keys and display of the s...

Page 5: ...on 1 2 F 2 Set the action when the input is active as follows 0 none 1 open 2 close Page 10 P205 Exit 2 Timer function F 0 Set the action when active as follows 0 none 1 open 2 close P206 Exit 2 Aerat...

Page 6: ...r function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close Page 12 P504 Exit 5 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 0 none 1 open 2 close...

Page 7: ...501 and P601 1 Deadman mode sensors and radio remote controls enabled When the n o contact is closed the station controls the forward back movement of the actuator until the contact is released All au...

Page 8: ...f the menu is used to save one or more channels of the PIK radio remote control in the station Page 16 The parameter dEL of the menu is used to delete one or more PIK radio remote controls saved previ...

Page 9: ...e electronic board of the station can occur only if the user already has a previously saved radio remote control Obtain the instructions manual of the PIK radio remote control for consultation The pro...

Page 10: ...ard schema HEATED RAIN SENSOR BLACK BLUE RED WIND SENSOR BLUE BROWN NO NC CONTACT COMMAND GENERAL C A TIMED THERMOSTAT V N L V POWER SUPPLY UNIT 110 230V AC 24 VDC 110 230 V LINE V V L N KEY OK EXPANS...

Page 11: ...ATION OF CONFORMITY The undersigned Company name NEKOS S r l Postal address Via Capitoni 7 5 Postcode and city 36064 Colceresa VI Telephone number 39 0424 411011 E mail address info nekos it declare t...

Page 12: ...Page 23 Notes Page 24 NEKOS S r l I 36064 COLCERESA VI Via Capitoni 7 5 Phone 39 0424 411011 Fax 39 0424 411013 info nekos it http www nekos it...

Reviews: