Repairs  should  only  be  performed  by  qualified  personnel  at  assistance 
centres authorised by the manufacturer.  
Always request original spare parts. Failure to respect this condition could 
compromise safety and invalidate the benefits contained in the warranty for 
the appliance. 

 

In the event of any problems or queries, consult your agent or contact the 
manufacturer directly. 

2.  CONSTRUCTION AND REGULATORY REFERENCES 

 

This product was designed to be used with products suitably studied for the 
specific application. If assembled incorrectly, use of the product with other 
devices may result in damage or malfunctions. 
The power supply system and electrical connection must comply with EU 
standards for electrical systems. 

The equipment has electrical insulation class I: it does require an earth 
wire.

 

All  the  devices  connected  to  the  control  units  must  be  manufactured 
according to current regulations. 

3.  TECHNICAL DATA 

Model 

KH2R 
KH2R 

KH4 

KH4R 

KH6 

KH6R 

KL2 

KL2R 

KL4 

KL4R 

KL6 

KL6R 

Power supply voltage of 
the station 

110-240V~ 50/60 Hz 

Maximum current 
absorbed from the 
electrical grid 

2,5A 

5A 

7,5A 

2A 

2,5A 

3A 

Output voltage 

110-240V~ 50/60 Hz 

24V

 

Maximum output current 

2x1,25A  4x1,25A 

6x1,25A  2x1,6A 

4x1,1A  6x1,1A 

Electrical insulation class 

Setup for connection to 
external devices 

Wind sensor – Rain sensor – Daily timer 

– Open/close command 

Operating temperature 

-5°C - +65ºC 

Degree of protection 

IP65 

The data provided in these illustrations is non-binding and subject to change, even without advance 

notice. 

4.  ID PLATE AND MARKING DATA 

KH../R

 and 

KL../R

 have 

 marking and are destined for use in the European Union 

without further requirements.

 

 

ID plate data are indicated on a polyethylene

 

adhesive label applied externally on the 

outside of the container, printed in black on a grey background.  

Page 6 

5.  RECOMMENDATIONS AND INSTRUCTIONS FOR ASSEMBLY  

T

HESE INSTRUCTIONS ARE INTENDED FOR TECHNICAL AND SPECIALIZED PERSONNEL

T

HUS BASIC SAFETY AND WORKING TECHNIQUES ARE NOT DISCUSSED

In order to guarantee perfect operation of the system and facilitate installation, follow 
the instructions and warnings below. 

 

Perform  a  thorough  visual  inspection  of  the  device  to  ensure  it  wasn't 
damaged during transport. 

 

To avoid the hazard of injury or death caused by the electrical current, always 
disconnect  the  voltage  from  the  power  supply  line  before  carrying  out  any 
wiring or adjustment operation. 

 

The  electrical  power  supply  system  must  be  designed  and  implemented  in 
compliance with current standards. 

 

Caution.

  Check  that  the  electric  power  supply  used  corresponds  to  that 

specified on the “technical data” label attached to the station. 

When assembling the KL../R and KH../R stations, in order to guarantee perfect operation 
of the system and facilitate installation, follow the instructions and warnings below. 
The rain and wind detectors are placed outside in direct contact with the weather, on the 
roof or in a similar position if possible.  
Some advises: 
A.  The rain sensor should be placed in a slightly inclined position in order to facilitate 

water run-off and in a position which is not protected from falling rain; positioning the 
sensor  underneath  trees  is  not  recommended  as  this  will  alter  the  natural 
meteorological event. 

B.  The wind sensor should be placed far from obstacles that deform or protect against 

the wind flow; thus avoid placing the sensor near gutters, trees, walls, etc. 

C. Select the most suitable location for the control unit based on the shape and structure 

of the building. The station does not require any maintenance, thus it can be placed 
in an out-of-the-way position, protected against direct weather exposure.  

D. Position the box of the device in the selected position and use a pencil to mark the 

drilling hole on the support (wall or other). 

E.  Drill  the  hole  using  a  drill  bit  with  diameter  corresponding  to  the  selected  plug  or 

fastening screw. 

F.  Mount the equipment box and fix the screws definitively. 
G. Drill the box to allow passage of the connection cables in the desired position using 

a  Ø10  drill  bit.  Remove  the  electronic  board  from  the  box  to  avoid  damaging  it 
permanently when drilling. 

H. Complete  the  path  of  the  electrical  connection  cables.  Make  the  electrical 

connections according to the wiring diagram provided on the following pages. 

I.  Perform the final test checking the intervention of the automatic devices and of all 

commands (see also paragraph 6.2). 

Summary of Contents for KL

Page 1: ...eriodically by qualified personnel from a service centre authorised by the manufacturer Do not use if repair or adjustment is required CAUTION Disconnect the power supply during cleaning or maintenanc...

Page 2: ...acturer after technical review of the assembly The device is not intended for use by persons including children with reduced physical sensory or mental capabilities or lacking experience and knowledge...

Page 3: ...warnings below Perform a thorough visual inspection of the device to ensure it wasn t damaged during transport To avoid the hazard of injury or death caused by the electrical current always disconnec...

Page 4: ...system A display is installed on the station whit a programming menu for all the station functions All the settings of the PXXX functional parameters must be made through the keys and display of the s...

Page 5: ...on 1 2 F 2 Set the action when the input is active as follows 0 none 1 open 2 close Page 10 P205 Exit 2 Timer function F 0 Set the action when active as follows 0 none 1 open 2 close P206 Exit 2 Aerat...

Page 6: ...r function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close Page 12 P504 Exit 5 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 0 none 1 open 2 close...

Page 7: ...501 and P601 1 Deadman mode sensors and radio remote controls enabled When the n o contact is closed the station controls the forward back movement of the actuator until the contact is released All au...

Page 8: ...f the menu is used to save one or more channels of the PIK radio remote control in the station Page 16 The parameter dEL of the menu is used to delete one or more PIK radio remote controls saved previ...

Page 9: ...e electronic board of the station can occur only if the user already has a previously saved radio remote control Obtain the instructions manual of the PIK radio remote control for consultation The pro...

Page 10: ...ard schema HEATED RAIN SENSOR BLACK BLUE RED WIND SENSOR BLUE BROWN NO NC CONTACT COMMAND GENERAL C A TIMED THERMOSTAT V N L V POWER SUPPLY UNIT 110 230V AC 24 VDC 110 230 V LINE V V L N KEY OK EXPANS...

Page 11: ...ATION OF CONFORMITY The undersigned Company name NEKOS S r l Postal address Via Capitoni 7 5 Postcode and city 36064 Colceresa VI Telephone number 39 0424 411011 E mail address info nekos it declare t...

Page 12: ...Page 23 Notes Page 24 NEKOS S r l I 36064 COLCERESA VI Via Capitoni 7 5 Phone 39 0424 411011 Fax 39 0424 411013 info nekos it http www nekos it...

Reviews: