Page 5
Repairs should only be performed by qualified personnel at assistance
centres authorised by the manufacturer.
Always request original spare parts. Failure to respect this condition could
compromise safety and invalidate the benefits contained in the warranty for
the appliance.
In the event of any problems or queries, consult your agent or contact the
manufacturer directly.
2. CONSTRUCTION AND REGULATORY REFERENCES
This product was designed to be used with products suitably studied for the
specific application. If assembled incorrectly, use of the product with other
devices may result in damage or malfunctions.
The power supply system and electrical connection must comply with EU
standards for electrical systems.
The equipment has electrical insulation class I: it does require an earth
wire.
All the devices connected to the control units must be manufactured
according to current regulations.
3. TECHNICAL DATA
Model
KH2R
KH2R
KH4
KH4R
KH6
KH6R
KL2
KL2R
KL4
KL4R
KL6
KL6R
Power supply voltage of
the station
110-240V~ 50/60 Hz
Maximum current
absorbed from the
electrical grid
2,5A
5A
7,5A
2A
2,5A
3A
Output voltage
110-240V~ 50/60 Hz
24V
Maximum output current
2x1,25A 4x1,25A
6x1,25A 2x1,6A
4x1,1A 6x1,1A
Electrical insulation class
I
Setup for connection to
external devices
Wind sensor – Rain sensor – Daily timer
– Open/close command
Operating temperature
-5°C - +65ºC
Degree of protection
IP65
The data provided in these illustrations is non-binding and subject to change, even without advance
notice.
4. ID PLATE AND MARKING DATA
KH../R
and
KL../R
have
marking and are destined for use in the European Union
without further requirements.
ID plate data are indicated on a polyethylene
adhesive label applied externally on the
outside of the container, printed in black on a grey background.
Page 6
5. RECOMMENDATIONS AND INSTRUCTIONS FOR ASSEMBLY
T
HESE INSTRUCTIONS ARE INTENDED FOR TECHNICAL AND SPECIALIZED PERSONNEL
.
T
HUS BASIC SAFETY AND WORKING TECHNIQUES ARE NOT DISCUSSED
.
In order to guarantee perfect operation of the system and facilitate installation, follow
the instructions and warnings below.
Perform a thorough visual inspection of the device to ensure it wasn't
damaged during transport.
To avoid the hazard of injury or death caused by the electrical current, always
disconnect the voltage from the power supply line before carrying out any
wiring or adjustment operation.
The electrical power supply system must be designed and implemented in
compliance with current standards.
Caution.
Check that the electric power supply used corresponds to that
specified on the “technical data” label attached to the station.
When assembling the KL../R and KH../R stations, in order to guarantee perfect operation
of the system and facilitate installation, follow the instructions and warnings below.
The rain and wind detectors are placed outside in direct contact with the weather, on the
roof or in a similar position if possible.
Some advises:
A. The rain sensor should be placed in a slightly inclined position in order to facilitate
water run-off and in a position which is not protected from falling rain; positioning the
sensor underneath trees is not recommended as this will alter the natural
meteorological event.
B. The wind sensor should be placed far from obstacles that deform or protect against
the wind flow; thus avoid placing the sensor near gutters, trees, walls, etc.
C. Select the most suitable location for the control unit based on the shape and structure
of the building. The station does not require any maintenance, thus it can be placed
in an out-of-the-way position, protected against direct weather exposure.
D. Position the box of the device in the selected position and use a pencil to mark the
drilling hole on the support (wall or other).
E. Drill the hole using a drill bit with diameter corresponding to the selected plug or
fastening screw.
F. Mount the equipment box and fix the screws definitively.
G. Drill the box to allow passage of the connection cables in the desired position using
a Ø10 drill bit. Remove the electronic board from the box to avoid damaging it
permanently when drilling.
H. Complete the path of the electrical connection cables. Make the electrical
connections according to the wiring diagram provided on the following pages.
I. Perform the final test checking the intervention of the automatic devices and of all
commands (see also paragraph 6.2).