nekos KL Instruction Manual Download Page 8

Page 15 

Activation  of  the  timer  command  affects  all  the  actuator  outputs  of  the  associated 
modules: exit 1-exit 2 of the first module, exit 3-exit 4 of the second module and exit 5-
exit 6 of the third module. 
The opening or closing of the windows can be set by the parameters P105-P205-P305-
P405-P505-P605. 

6.3.5.  Sensor priority – Parameter P006 

By  means  of  parameter  P006,  higher  priority  can  be  assigned  to  one  of  the  sensors 
(wind-rain-timer) in case events occur simultaneously. 

Attention. 

In case events occur simultaneously, the unit will follow these priorities: 

1.  General manual command 
2.  Single manual command 
3.  Remote control 
4.  Sensors 

5. 

Aeration

 

6. 

Restoration

 

6.3.6.  Exit reset time – Parameters P102, P202, P302, P402, P502, P602 

After intervention of the sensors (rain, wind) and the reset time set by parameter P102 
– P202 – P302 – P402 – P502 – P602 has passed, the window returns to the previous 
scenario.  

Caution

If you do not want to use this function, leave the parameter P102 – P202 – P302 – P402 
– P502 – P602

 = 0

 

With  P102  –  P202  –  P302  –  P402  –  P502  –  P602  =  0,  when  one  or  more  sensors 
intervene the window goes to the position instructed by the sensor with higher priority 
and remains there. 

6.3.7.  Output  ventilation  time  –  Parameters  P106,  P206,  P306,  P406, 

P506 and P606 

The  Ventilation  function  is  for  automatically  ventilating  the  room.  To  activate  this 
function, press the F1 and arrow ▲buttons in sequence on the radio remote control. 
The window opens for the set time and then closes again automatically, unless other 
commands are given. If a rain sensor signal or a manual or radio-controlled command 
is  given,  the  ventilation  function  is  interrupted;  to  restore  the  function,  the  button 
sequence must be repeated. 
The set time also includes the opening time of the actuator. 

6.3.8.  Other  parameters  –  Parameters  P101,  P201,  P301,  P401,  P501, 

P601, Add, dEL, ReTx, rESE  

-  The parameter P101 – P201 – P301 – P401 – P501 – P601 is used to set the 

work time of the exit. 

-  The parameter “

Add

” of the menu is used to save one or more channels of the 

PIK radio remote control in the station. 

Page 16 

-  The parameter “

dEL

” of the menu is used to delete one or more PIK radio remote 

controls saved previously. 

-  The parameter “

ReTx

” of the menu is used to delete all PIK radio remote controls 

from the memory. 

-  The  parameter  “

rESE

”  of  the  menu  is  used  to  restore  the  factory-set  values 

(Default). 

6.4. 

Saving a PIK radio remote control 

This paragraph concerns only the KL_R or KH_R units equipped with PIK radio remote 
control. 

T

HE CONTROL UNITS LEAVE THE FACTORY WITH THE REMOTE CONTROL ALREADY INSERTED IN 

THE MEMORY

;

 CARRY OUT THE MEMORIZATION PROCEDURE ONLY IF YOU WANT TO ASSOCIATE 

OTHERS

The remote electronic control provided with KL_R and KH_R units is equipped with 30 
selectable  channels.  Each  command  channel  is  connected  to  one  unit  exit. 
Opening/closure/stop  of  each  exit  can  be  commanded  using  arrow  ▲/▼  and  STOP 
buttons. 

For more details on the characteristics and operation of the 

PIK

 radio remote control, 

consult the instructions manual provided with the radio remote control itself; 

not all the 

functions of the radio remote control are listed in this manual.

 

The KL_R or KH_R station can accept maximum up to 6 PIK radio remote controls. 
Memorizing procedure: 

-  Equip  yourself  with  the  radio  remote  control,  checking  beforehand  that  it  is 

working, has charged batteries and is in good condition. 

-  Select the “Add” item in the unit menu. 

-  Press the “OK” button. 

-  The message “Push” will appear on the display. 

-  On  the  PIK  radio  remote  control 

(see  the  instructions  provided  with  the  radio 

remote control)

, select any channel between CH1 and CH6 and press any one of 

the ▲/▼ ARROW or STOP buttons on the PIK for about 1 second. 

-  The “OK” message will appear on the unit display, indicating that the memorizing 

process was successful. 

-  The  radio  remote  control  is  now  saved  and  the  actuators  are  controlled  by  the 

respective channels. (CH1=exit 1; CH2=exit 2….. CH6=exitr 6). 

In case of full memory “

FULL

” message appears on the display. 

In case of remote control not associated “

Err

” message appears on the display. 

Repeat the procedure for any other radio remote controls. 

 

Summary of Contents for KL

Page 1: ...eriodically by qualified personnel from a service centre authorised by the manufacturer Do not use if repair or adjustment is required CAUTION Disconnect the power supply during cleaning or maintenanc...

Page 2: ...acturer after technical review of the assembly The device is not intended for use by persons including children with reduced physical sensory or mental capabilities or lacking experience and knowledge...

Page 3: ...warnings below Perform a thorough visual inspection of the device to ensure it wasn t damaged during transport To avoid the hazard of injury or death caused by the electrical current always disconnec...

Page 4: ...system A display is installed on the station whit a programming menu for all the station functions All the settings of the PXXX functional parameters must be made through the keys and display of the s...

Page 5: ...on 1 2 F 2 Set the action when the input is active as follows 0 none 1 open 2 close Page 10 P205 Exit 2 Timer function F 0 Set the action when active as follows 0 none 1 open 2 close P206 Exit 2 Aerat...

Page 6: ...r function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close Page 12 P504 Exit 5 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 0 none 1 open 2 close...

Page 7: ...501 and P601 1 Deadman mode sensors and radio remote controls enabled When the n o contact is closed the station controls the forward back movement of the actuator until the contact is released All au...

Page 8: ...f the menu is used to save one or more channels of the PIK radio remote control in the station Page 16 The parameter dEL of the menu is used to delete one or more PIK radio remote controls saved previ...

Page 9: ...e electronic board of the station can occur only if the user already has a previously saved radio remote control Obtain the instructions manual of the PIK radio remote control for consultation The pro...

Page 10: ...ard schema HEATED RAIN SENSOR BLACK BLUE RED WIND SENSOR BLUE BROWN NO NC CONTACT COMMAND GENERAL C A TIMED THERMOSTAT V N L V POWER SUPPLY UNIT 110 230V AC 24 VDC 110 230 V LINE V V L N KEY OK EXPANS...

Page 11: ...ATION OF CONFORMITY The undersigned Company name NEKOS S r l Postal address Via Capitoni 7 5 Postcode and city 36064 Colceresa VI Telephone number 39 0424 411011 E mail address info nekos it declare t...

Page 12: ...Page 23 Notes Page 24 NEKOS S r l I 36064 COLCERESA VI Via Capitoni 7 5 Phone 39 0424 411011 Fax 39 0424 411013 info nekos it http www nekos it...

Reviews: