6.  TECHNICAL OPERATING INFORMATION 

6.1.  General instructions 

The  control  unit  is  composed  of  a  “mother  board”  which  is  set  up  for  insertion  of 
“expansion module boards”.  
The “expansion module” boards differ depending on the control voltage of the motors. 
The modules can be for 24V

 actuators or 100/240V~ 50/60Hz ones. 

The control unit is set up for insertion of a maximum of 3 “expansion modules”. Each 
expansion module has 2 exits and can control more actuators; this number has to be 
decided on the basis of their nominal absorption. In case of doubts take contact with the 
producer. 

Caution:

 using 24V

 actuators chose the unit with the suitable output power. 

 

Model 

Number of expansion modules 

(Control voltage) 

Number of exits 

provided for 

KH2 – KH2R 

1   – (110-240V~ 50/60Hz) 

KH4 – KH4R 

2   – (110-240V~ 50/60Hz) 

KH6 – KH6R 

3   – (110-240V~ 50/60Hz) 

KL2 – KL2R 

1  – (24V

KL4 – KL4R 

2  – (24V

)

 

KL6 – KL6R 

3  – (24V

)

 

Each expansion module has inputs for manual open/close controls for each individual 
actuator (local command); instead, inputs for all actuators controls (general command) 
are placed in the “mother board”. We recommend the use of 

n.o

. (normally open) type 

interlock switch buttons, see parameter P*07 for associated functions. The 

KL..R 

and

 

KH..R

 models allow the use of the 

PIK

 radio remote control with 433.92 MHz proprietary 

protocol, as well as manual control.

 

6.2.  Programming  

6.2.1.  Programming Display and Programming Menu 

The following information and instruction are important for the functioning of the 
whole system.

 

A display is installed on the station whit a programming menu for all the station functions. 
All the settings of the 

PXXX

 functional parameters must be made through the keys and 

display of the station, changing the preset values 

F

 [factory-set].  

 The 

OK

 key is used to enter the programming menu and confirm the setting of each 

individual parameter. 

 The 

+

 

(plus)

 key is used to scroll up through the programming menu or increase the 

value of the parameter within the menu. 

 The 

 

(minus)

 key is used to scroll down through the programming menu or decrease 

the value of the parameter within the menu. 

Page 8 

 The 

(plus)

 

 

and

 –

 

(minus)

 keys pressed together are used to exit the programming 

menu. 

 

IMPORTANT:  the  change  of  some  parameters  can  compromise  the 
functioning and the desired security level. 

 

(display) 

The initial menu is free of any writing when no input is active; otherwise it 
shows the activated function with the following messages: 

­

 

In01   

- general Open 

­

 

In02   

- general Close 

­

 

In11   

- actuator 1 Open 

­

 

In12   

- actuator 1 Close 

­

 

In21   

- actuator 2 Open 

­

 

In22   

- actuator 2 Close 

­

 

In31   

- actuator 3 Open 

­

 

In32   

- actuator 3 Close 

­

 

In41   

- actuator 4 Open 

­

 

In42   

- actuator 4 Close 

­

 

In51   

- actuator 5 Open 

­

 

In52   

- actuator 5 Close 

­

 

In61   

- actuator 6 Open 

­

 

In62   

- actuator 6 Close 

­

 

pk01   

- channel 01 of the PIK radio remote control 

­

 

u Km

  - wind speed 

­

 

r

         - rain state 

­

 

cron

    - timed thermostat / timer 

Pressing 

+

 (plus) and – (minus) together it’s displayed the total number of 

PIK radio remote control saved in the memory. 

 

-↑    +↓ 

     P001 

Wind sensor activation threshold (5 - 50) Km/h  F[30] 

-↑    +↓ 

P005 

Rain sensor exclusion time (0 - 10) min F[0]  

-↑    +↓ 

P006 

Sensor priority (1 - 3) F[1]. Priority can be selected for only one sensor, 
where: 

  1=rain 

  2=wind, 3=timer 

-↑    +↓ 

P101 

Exit 1

 work time (10 - 240) s  F[60] 

Summary of Contents for KL

Page 1: ...eriodically by qualified personnel from a service centre authorised by the manufacturer Do not use if repair or adjustment is required CAUTION Disconnect the power supply during cleaning or maintenanc...

Page 2: ...acturer after technical review of the assembly The device is not intended for use by persons including children with reduced physical sensory or mental capabilities or lacking experience and knowledge...

Page 3: ...warnings below Perform a thorough visual inspection of the device to ensure it wasn t damaged during transport To avoid the hazard of injury or death caused by the electrical current always disconnec...

Page 4: ...system A display is installed on the station whit a programming menu for all the station functions All the settings of the PXXX functional parameters must be made through the keys and display of the s...

Page 5: ...on 1 2 F 2 Set the action when the input is active as follows 0 none 1 open 2 close Page 10 P205 Exit 2 Timer function F 0 Set the action when active as follows 0 none 1 open 2 close P206 Exit 2 Aerat...

Page 6: ...r function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close Page 12 P504 Exit 5 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 0 none 1 open 2 close...

Page 7: ...501 and P601 1 Deadman mode sensors and radio remote controls enabled When the n o contact is closed the station controls the forward back movement of the actuator until the contact is released All au...

Page 8: ...f the menu is used to save one or more channels of the PIK radio remote control in the station Page 16 The parameter dEL of the menu is used to delete one or more PIK radio remote controls saved previ...

Page 9: ...e electronic board of the station can occur only if the user already has a previously saved radio remote control Obtain the instructions manual of the PIK radio remote control for consultation The pro...

Page 10: ...ard schema HEATED RAIN SENSOR BLACK BLUE RED WIND SENSOR BLUE BROWN NO NC CONTACT COMMAND GENERAL C A TIMED THERMOSTAT V N L V POWER SUPPLY UNIT 110 230V AC 24 VDC 110 230 V LINE V V L N KEY OK EXPANS...

Page 11: ...ATION OF CONFORMITY The undersigned Company name NEKOS S r l Postal address Via Capitoni 7 5 Postcode and city 36064 Colceresa VI Telephone number 39 0424 411011 E mail address info nekos it declare t...

Page 12: ...Page 23 Notes Page 24 NEKOS S r l I 36064 COLCERESA VI Via Capitoni 7 5 Phone 39 0424 411011 Fax 39 0424 411013 info nekos it http www nekos it...

Reviews: