P401 

Exit 4

 Work time (10 - 240) s  F[60] 

-↑    +↓ 

P402 

Exit 4

 Reset time (0 - 60)min  F[0] 

If F[0] the function is not on. 

-↑    +↓ 

P403 

Exit  4

 Wind sensor function (0  -  2)  F[0]. Set  the action  when  active  as 

follows:  

  0=none 

  1=open 

  2=close 

-↑    +↓ 

P404 

Exit 4

 Rain sensor function (1 - 2) F[2]. Set the action when the input is 

active, as follows: 

  0=none 

  1=open 

  2=close 

-↑    +↓ 

P405 

Exit 4 

Timer function F[0].  Set the action when active as follows:  

  0=none 

  1=open 

  2=close 

-↑    +↓ 

P406 

Exit 4 

Aeration time (1-60)min F[10]. 

-↑    +↓ 

P407 

Exit 4

 Single manual command functioning mode:  

  0=half-automatic mode 

  1=dead-man mode, sensors and remote controls enabled 

  2= dead-man mode, sensors and remote controls disabled 

-↑    +↓ 

P501 

Exit 5

 Work time (10 - 240) s  F[60] 

-↑    +↓ 

P502 

Exit 5

 Reset time (0 - 60)min  F[0] 

If F[0] the function is not on. 

-↑    +↓ 

P503 

Exit  5

 Wind sensor function (0  -  2)  F[0]. Set  the action  when  active  as 

follows: 

  0=none 

  1=open 

  2=close 

Page 12 

-↑    +↓ 

P504 

Exit 5

 Rain sensor function (1 - 2) F[2]. Set the action when the input is 

active, as follows: 

  0=none 

  1=open 

  2=close 

-↑    +↓ 

P505 

Exit 5

 Timer function F[0].  Set the action when active as follows:  

  0=none 

  1=open 

  2=close 

-↑    +↓ 

P506 

Exit 5

 Aeration time (1-60)min F[10]. 

-↑    +↓ 

P507 

Exit 5

 Single manual command functioning mode:  

  0=half-automatic mode 

  1=dead-man mode, sensors and remote controls enabled 

  2= dead-man mode, sensors and remote controls disabled 

-↑    +↓ 

P601 

Exit 6

 Work time (10 - 240) s  F[60] 

-↑    +↓ 

P602 

Exit 6

 Reset time (0 - 60)min  F[0] 

If F[0] the function is not on. 

-↑    +↓ 

P603 

Exit  6

 Wind sensor function (0  -  2)  F[0]. Set  the action  when  active  as 

follows:   

  0=none 

  1=open 

  2=close 

-↑    +↓ 

P604 

Exit 6

 Rain sensor function (1 - 2) F[2]. Set the action when the input is 

active, as follows:  

  0=none 

  1=open 

  2=close 

-↑    +↓ 

P605 

Exit 6

 Timer function F[0].  Set the action when active as follows:  

  0=none 

  1=open 

  2=close 

-↑    +↓ 

P606 

Exit 6

 Aeration time (1-60)min F[10]. 

Summary of Contents for KL

Page 1: ...eriodically by qualified personnel from a service centre authorised by the manufacturer Do not use if repair or adjustment is required CAUTION Disconnect the power supply during cleaning or maintenanc...

Page 2: ...acturer after technical review of the assembly The device is not intended for use by persons including children with reduced physical sensory or mental capabilities or lacking experience and knowledge...

Page 3: ...warnings below Perform a thorough visual inspection of the device to ensure it wasn t damaged during transport To avoid the hazard of injury or death caused by the electrical current always disconnec...

Page 4: ...system A display is installed on the station whit a programming menu for all the station functions All the settings of the PXXX functional parameters must be made through the keys and display of the s...

Page 5: ...on 1 2 F 2 Set the action when the input is active as follows 0 none 1 open 2 close Page 10 P205 Exit 2 Timer function F 0 Set the action when active as follows 0 none 1 open 2 close P206 Exit 2 Aerat...

Page 6: ...r function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close Page 12 P504 Exit 5 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 0 none 1 open 2 close...

Page 7: ...501 and P601 1 Deadman mode sensors and radio remote controls enabled When the n o contact is closed the station controls the forward back movement of the actuator until the contact is released All au...

Page 8: ...f the menu is used to save one or more channels of the PIK radio remote control in the station Page 16 The parameter dEL of the menu is used to delete one or more PIK radio remote controls saved previ...

Page 9: ...e electronic board of the station can occur only if the user already has a previously saved radio remote control Obtain the instructions manual of the PIK radio remote control for consultation The pro...

Page 10: ...ard schema HEATED RAIN SENSOR BLACK BLUE RED WIND SENSOR BLUE BROWN NO NC CONTACT COMMAND GENERAL C A TIMED THERMOSTAT V N L V POWER SUPPLY UNIT 110 230V AC 24 VDC 110 230 V LINE V V L N KEY OK EXPANS...

Page 11: ...ATION OF CONFORMITY The undersigned Company name NEKOS S r l Postal address Via Capitoni 7 5 Postcode and city 36064 Colceresa VI Telephone number 39 0424 411011 E mail address info nekos it declare t...

Page 12: ...Page 23 Notes Page 24 NEKOS S r l I 36064 COLCERESA VI Via Capitoni 7 5 Phone 39 0424 411011 Fax 39 0424 411013 info nekos it http www nekos it...

Reviews: