INSTALLER INSTRUCTIONS 

 

 
 

nekos

 products have been manufactured in accordance with safety standards and 

conforms to the stipulations of current standards in force.  
When correctly assembled, installed and used according to the present instructions, they 
will not generate any danger for persons, animals or items.  
 
 
 

Symbols used in the manual 

 

 

DANGER 

This indication draw the attention about potential dangers 
for safety and health of peoples and animals. 

 

 

Contents  

1. 

SAFETY INDICATIONS .............................................................................................. 4 
1.1.  General notes ..................................................................................................... 4 
1.2.  Notes for installer ................................................................................................ 4 

2. 

CONSTRUCTION AND REGULATORY REFERENCES ............................................. 5 

3. 

TECHNICAL DATA ..................................................................................................... 5 

4. 

ID PLATE AND MARKING DATA ................................................................................ 5 

5. 

RECOMMENDATIONS AND INSTRUCTIONS FOR ASSEMBLY  .............................. 6 

6. 

TECHNICAL OPERATING INFORMATION ................................................................ 7 
6.1.  General instructions ............................................................................................ 7 
6.2.  Programming  ..................................................................................................... 7 
6.3.  Settable functions ............................................................................................. 13 
6.4.  Saving a PIK radio remote control ..................................................................... 16 
6.5.  Saving a radio remote control without access to the board ................................ 17 

7. 

OVERALL DIMENSIONS  ......................................................................................... 18 

8. 

CONNECTION DIAGRAM OF THE STATION  .......................................................... 19 

9. 

ENVIRONMENTAL PROTECTION ........................................................................... 21 

10.  CERTIFICATE OF GUARANTEE .............................................................................. 21 
11.  DECLARATION OF CONFORMITY .......................................................................... 22 

 
 
 
 

Page 4 

1.  SAFETY INDICATIONS 

1.1.  General notes 

 

ATTENTION:  Before  installing  this  appliance,  ensure  all  safety 
indications  have  been  read  carefully  and  understood  in  order  to 
prevent  contact  with  electricity,  injury  or  any  other  incident.  The 
manual should be conserved for further consultation at a later date. 

 

The  manufacturer  accepts  no  responsibility  for  damage  to  people, 

animals  or  things  incurred  by  improper  use  or  inobservance  of  the 
basic safety rules described in this manual. 

 

Use for any applications other than those indicated must be authorised 

by the manufacturer after technical review of the assembly. 

 

The  device  is  not  intended  for  use  by  persons  (including  children)  with 
reduced physical, sensory or mental capabilities, or lacking experience and 
knowledge. Do not allow children to play with the fixed controls and keep 
any remote-control units out of their reach. 

 

Do not use solvents or jets of water to wash the appliance.  

1.2.  Notes for installer 

 

This  device  is  intended  only  and  exclusively  for  the  use  for  which  it  was 
designed,  and  the  manufacturer  cannot  be  held  liable  for  damage  due  to 
improper use. 

KH../R

  and 

KL../R

  have  been  designed  and  constructed  exclusively  to  execute 

maneuvers for closing and/or opening windows, roll-up blinds, curtains and sunshades, 
assisted by the aid of sensors for rain and wind. 
Specific use is reserved for automatic ventilation and air-conditioning of rooms, which 
is carried out through the connected motors. 

 

The  appliance  must  be  installed  by  competent  and  qualified  technical 
personnel  following  manufacturer’s  indications.  Improper  installation  and 
use make the unit dangerous for people and things. 

 

A device which assures the complete omnipolar disconnection from the grid, 
with  minimum  distance  of  3  mm  between  contacts,  should  be  installed 
upstream of the automation control line.

 

 

The  box  containing  the  electric  panel  must  be  placed  in  a  proper 
environment, fixed with suitable screws and using its supports. 

 

For the electrical connection to feeding grid use cables suitable for power 
supply in buildings and other civil engineering works, e.g. H05VV-F type. 

 

Before carrying out any cleaning or maintenance, make sure the equipment 
has been disconnected from the electricity supply. 

 

Attention: 

in the event of breakage or malfunction, switch the appliance off 

at the general switch and call for the services of a qualified technician. 

Summary of Contents for KL

Page 1: ...eriodically by qualified personnel from a service centre authorised by the manufacturer Do not use if repair or adjustment is required CAUTION Disconnect the power supply during cleaning or maintenanc...

Page 2: ...acturer after technical review of the assembly The device is not intended for use by persons including children with reduced physical sensory or mental capabilities or lacking experience and knowledge...

Page 3: ...warnings below Perform a thorough visual inspection of the device to ensure it wasn t damaged during transport To avoid the hazard of injury or death caused by the electrical current always disconnec...

Page 4: ...system A display is installed on the station whit a programming menu for all the station functions All the settings of the PXXX functional parameters must be made through the keys and display of the s...

Page 5: ...on 1 2 F 2 Set the action when the input is active as follows 0 none 1 open 2 close Page 10 P205 Exit 2 Timer function F 0 Set the action when active as follows 0 none 1 open 2 close P206 Exit 2 Aerat...

Page 6: ...r function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close Page 12 P504 Exit 5 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 0 none 1 open 2 close...

Page 7: ...501 and P601 1 Deadman mode sensors and radio remote controls enabled When the n o contact is closed the station controls the forward back movement of the actuator until the contact is released All au...

Page 8: ...f the menu is used to save one or more channels of the PIK radio remote control in the station Page 16 The parameter dEL of the menu is used to delete one or more PIK radio remote controls saved previ...

Page 9: ...e electronic board of the station can occur only if the user already has a previously saved radio remote control Obtain the instructions manual of the PIK radio remote control for consultation The pro...

Page 10: ...ard schema HEATED RAIN SENSOR BLACK BLUE RED WIND SENSOR BLUE BROWN NO NC CONTACT COMMAND GENERAL C A TIMED THERMOSTAT V N L V POWER SUPPLY UNIT 110 230V AC 24 VDC 110 230 V LINE V V L N KEY OK EXPANS...

Page 11: ...ATION OF CONFORMITY The undersigned Company name NEKOS S r l Postal address Via Capitoni 7 5 Postcode and city 36064 Colceresa VI Telephone number 39 0424 411011 E mail address info nekos it declare t...