VP1007-B / Installation manual
Version 01.000 / November 2020 / EN
18
Livestock Management
6 Troubleshooting
Errors and malfunctioning of the VP1007-B are indicated by the indicator LEDs or codes on the display.
Indicator LED
Indicator LEDs are normally green (except the blue Status LED) or switched off. A red or orange indicator LED
usually means there is something not functioning correctly. See
VP1007-B reader LED indicators (page 25)
for
the explanation of the various colors.
Display code
Codes on the display are normally controlled by the VPU. The error will be indicated in the Velos web interface.
If the VP1007-B is part of a complete Nedap system, see the Troubleshooting section in the installation
manual of this system. The installation manual can be obtained from your dealer or on our Business portal:
http://www.nedap.com/livestockmanagement-portal
.
Error codes shown with menu option "dE"
Actual error codes can be displayed with menu option
dE
:
1. Select option
dE
VP1007-B reader menu overview (page 26)
).
The error code will be displayed.
Multiple error codes will be displayed one after another with a short gap between each code.
2. Press the button to clear the error.
3. If the error code is not cleared, the error could not be solved automatically. Try to solve the error.
Error
code
Description
Possible solution(s)
00
No errors
No action
03
Power to outputs turned off (high side)
Test outputs one by one via
it
menu option
04
Power to outputs turned off (low side)
Test outputs one by one via
it
menu option
09
Output 1: output error. Possibly caused by error 01
to 08.
Check connected device on output 1
10
Output 2: output error. Possibly caused by error 01
to 08.
Check connected device on output 2
11
Output 3: output error. Possibly caused by error 01
to 08.
Check connected device on output 3
12
Output 4: output error. Possibly caused by error 01
to 08.
Check connected device on output 4
13
Current too high (> 8 A) to next V-packs: Power to
next V-pack switched off
•
Disconnect all next V-packs
•
Reconnect next V-packs one by one and check
Vi LED (green)
17
CAN bus high voltage (> 10 V): CAN terminator
shut off
•
Check CAN cable for damages or shortcuts
•
Check connectors