NED
RMSL6K17GE
UM-0099-03
40
different as follows.
(Example)
・
When Acquisition Line Rate is set to 7000Hz, the real set value becomes 7002Hz.
・
When Acquisition Line Rate is set to 12000Hz, the real set value becomes 12004Hz.
The value of Exposure Time may be changed automatically when the value of Acquisition
Line Rate is too large.
The values are roughly set according to the following formula.
Exposure Time
<= (
1
/
Acquisition Line Rate
)
- 2.3
μ
s
4.2.4.2
Setting Trigger Selector
Sets the Trigger.
・
Register name
Trigger Selector
・
VAL Frame Active,
Exposure Start or
DummyFrameOutput
(Example)
Trigger Selector : Exposure Start
4.2.4.3
Setting Permission for using External Trigger
Sets the “Trigger Mode” of Register name to get permission for using the External
trigger. Select
“On” on the “Trigger Mode” if the External trigger is used.
・
Register name
Trigger Mode
・
VAL Off / On
(Disable/Enable)
(Example)
Trigger Mode: On