4.2.3.2
Height Setting
The Height parameter is used to set the number of lines in 1 frame.
The range of values is as follows:
・
Height
:
16~4096
OffsetX
Width
He
ight
1Frame
Figure 4-2-3-2
Area of 1 Frame
Notes:
The time for 1 frame can be calculated as follows:
1 Frame period (us)
=
1 Line Scan Period (us) x Height
Depending on the scan period and the height setting, it is possible that your
application may time out.
In such a case, either change the above settings or the timeout period in your
application.