NED
U M-0099-03
RMSL6K17GE
41
*
Make sure that the trigger packet is supplied from the frame grabber board to the camera
before the
“Trigger Mode” is changed from “Off(Disable) to “On(Enable)” to get permission for
using the External trigger.
See 4.3 Examples of External trigger setting.
4.2.4.4
Setting Exposure Mode
Sets the “Exposure Mode” of Register name when the “Trigger Mode” is set
to “On” (Enable).
・
Register name
Exposure Mode
・
VAL Timed
(The set value of the “Exposure Time” is used as the exposure time)
Trigger Width (The
“H” time of “Trigger pulse” of the “External Start” is used
as the exposure time)
(Example)
Exposure Mode : Timed