background image

 

17 

 

 
 
 

 

 

GLEN DIMPLEX AUSTRALIA PTY LTD 

ABN 69 118 275 460

 

Head Office/Factory/Showroom

 

1340 Ferntree Gully Rd.

 

Scoresby Vic 3179

 

Ph: (03) 8706 2000 Fax: (03) 8706 2001

 

E-mail[email protected] 

Richmond - VIC Showroom

 

300 Swan St.

 

Richmond Vic 3121

 

Ph: (03) 9428 4443 Fax: (03) 9428 4445

 

Dandenong - VIC Showroom  

3/328 South Gippsland Highway, Dandenong South Vic 3164

 

Ph: (03) 9702 7853

 

E-mail[email protected]

 

Geelong - VIC Showroom

 

1/2A Gordon Avenue. Geelong West Vic 3218 Ph/Fax: 5229 0844

 

E-mail[email protected]

 

Sydney - NSW Showroom

 

546 Pacific Highway.

 

Chatswood NSW 2067

 

Ph: (02) 8905 0189 Fax: (02) 8905 0192

 

E-mail[email protected]

 

Miranda - NSW Showroom

 

36 Kareena Rd.

 

Miranda NSW 2228

 

Ph: (02) 8513 6202  Fax: (02) 9520  1974

 

E-mail:  [email protected]

 

Adelaide - SA Showroom

 

173 -175 Magill Rd.

 

Norwood SA 5067

 

Ph: (08) 8132 0371 Fax: (08) 8132 1687

 

E-mail[email protected]

 

 

Milton - QLD Showroom 

 

46 Douglas St,

 

Milton QLD 4064

 

Ph: (07) 3368 2011

 

Perth 

– WA Showroom  

47-53 McDonald St East, Osborne Park WA 6017

 

Ph: (08) 9444 9900 Fax: (08) 9444 9800

 

Fyshwick 

– ACT Showroom

 

88 Wollongong St,

 

Fyshwick ACT 2609

 

Ph: (02) 6280  5522

 

Ulverstone 

– TAS Showroom

 

31A Victoria St, Ulverstone TAS  7315

 

Ph: (03) 6425  4440 

Summary of Contents for 2000

Page 1: ...EESTANDING SPACE HEATER SERVICE INSTRUCTIONS REV 2 Do not modify this appliance Freestanding gas appliance Natural gas only Approval no AGA 5954G Warning Servicing shall be carried out only by authori...

Page 2: ...LAMES MAY EXHIBIT SLIGHT CARBON DEPOSIT NOTE A slight smell may be apparent for the first few hours of use This is due to the heat resistant paint curing It is recommended to open windows in the room...

Page 3: ...7 MEDIA INSTALLATION 9 COMMISSIONING PROCEDURE 10 BURNER PRESSURE ADJUSTMENT 11 IGNITION ADJUSTMENTS SPARK GAPS 12 AERATION ADJUSTMENTS 12 DOOR GLASS GLASS SEAL REPLACEMENT 13 DOOR REMOVAL REPLACEMEN...

Page 4: ...ance Natural Gas 1 13Kpa 5 00Kpa Installation must meet Australian gas codes AS NZS 5601 1 2013 DIMENSIONS INSTALLATION CLEARANCES clearances from combustible materials GAS CONNECTION 15mm 1 2 Compres...

Page 5: ...sures Appliance must be installed as per gas installation code AS NZS 5601 1 2013 and applicable electrical installation code AS3000 Test for gas leaks prior to operating appliance Check gas pressures...

Page 6: ...s happens the heater is reset by simply turning the ON OFF switch to OFF wait 30 seconds and then turn ON again The burner of the fire will light with a soft blue flame You may see some moisture appea...

Page 7: ...connection between burner and body and earth connections between control unit and body Replace Reconnect Igniter sparks but no ignition No gas Air in line Check supply Purge gas line Note reset ignit...

Page 8: ...ter waiting 30 seconds Flame abnormality Incorrect pressure Dirt in jet or burner Log arrangement incorrect Check gas pressure high and low Clean jet and burner Check log and ember effect against inst...

Page 9: ...box front door of the unit by removing the locking screw at the base of the main handle Remove the inside glass by loosening the two screws of the left hand glass retainer bracket Remove the two scre...

Page 10: ...ling coals and or logs and ensure children do not handle them as the colouring may contain toxic dies COMMISSIONING PROCEDURE Once the fire is installed Install media Refit doors glass Connect to gas...

Page 11: ...rol is showing maximum flame Using 10mm spanner or similar adjust maximum gas rate by turning outer brass nut to the correct test point pressure kPa 6 Turn appliance down to minimum rate using remote...

Page 12: ...onversion the correct pilot and pilot orifice must be used AERATION ADJUSTMENTS The aeration is factory set and fixed on all burners and should not be adjusted Flame sensing rod runs across burner hei...

Page 13: ...in place 8 Ensure glass is sitting firm against seal with no gaps or bows 9 Refit door 10 Refit brackets Refit door screws Note tighten screws hand tight DO NOT OVERTIGHTEN OR STRIP THREADS 11 Close...

Page 14: ...s been used the ceramic base board is extremely delicate To reassemble refit the burner and reconnect the gas pipe and two wires to the central spark generator connector on the electronic control Befo...

Page 15: ...15 WIRING DIAGRAM CONVERSION DETAILS Appliance available as Natural gas only...

Page 16: ...16 PARTS LIST 1 Valve SIT 843 SIGMA 2 Injector 3 Burner 4 Ignition pack gas control SIT 579 402 2 3 4 1...

Page 17: ...eelong hotmail com au Sydney NSW Showroom 546 Pacific Highway Chatswood NSW 2067 Ph 02 8905 0189 Fax 02 8905 0192 E mail info realflame com au Miranda NSW Showroom 36 Kareena Rd Miranda NSW 2228 Ph 02...

Reviews: