© by N&W GLOBAL VENDING S.p.A.
38
12 2008 3335 00
gsm
The control software can send a signal of faulty machine,
“prealarms” or “ending product” via GSM modem after
a (programmable) well-defined number of dispensing
cycles of a given product.
p
iN
coDE
Function used to programme the identification code that
will be sent to the GSM modem (optional) as soon as
the machine is powered on.
t
HrEsHolD
sEtup
Function used to define the number of pieces or grams
of powder of a well-defined product, after which to signal
an “ending product” prealarm via modem.
c
ouNtEr
rEsEt
Function used to reset the counters intended to manage
pre-alarms.
b
aNk
NumbEr
The bank number (from 1 to 7) is intended to univocally
define the machines acting as a “GSM slave”, i.e. send
-
ing the data by means of the “master” machine modem.
0 is intended to identify the machine directly connected
with the modem, i.e. the “GSM master”, in a bank.
failurES
The machine is equipped with several sensors intended
to control the various functional units.
As soon as a malfunction is found out, the type of failure
is displayed and the machine (or part of it) is set out of
order.
The failures are stored in special counters.
FaIluREs
FaIluRE REaDout
FaIluRE REsEt
MotoR ERRoRs
MotoR ERRoR REsEt
FaIluRE HIstoRY FIlE
TECH> x.x
f
ailurE
rEaDout
Function used to display the current failures.
Press the Enter key
�
to display the current failures.
If there is no failure at the moment, the “Failure end”
message will appear on the display by pressing key
�
.
Possible failures are listed here below:
compressor:
-
the machine stops if the compressor is
working for over twenty-four consecutive hours.
coin mechanism:
-
The machine stops if it should
receive an over 2-sec. pulse on a validator line or if the
communication with the coin mechanism is not longer
than 30 (Executive protocol) or 75 (BDV protocol)
seconds.
ram data:
-
one or more than one area of the RaM
memory contain altered data that have been corrected
by default values.
Probe:
-
The machine stops after 5 minutes if the probe
is found out to be electrically interrupted (the display
shows -11°C).
The machine stops after 1 hour if a probe short-circuit
is found out (the display shows +41°C).
motor error
-
: The machine displays all faulty motors.
Faulty motors are displayed every 1 second.
Note:
If you power on the machine again, any faulty
motor is found out as not available.
Summary of Contents for Samba Top
Page 1: ...InstallaTIon OPERATION MaIntenANCE EN English Doc No H3335EN00 Edition 1 12 2008 Samba Top...
Page 2: ......
Page 5: ......
Page 6: ......
Page 68: ...Sx49600...
Page 69: ...Samba Plus Top SCHEMA ELETTRICO WIRING DIAGRAM...
Page 70: ...Sx49700...
Page 71: ...Samba Plus Top Schema elettrico porta Door wiring diagram...
Page 72: ...Custom version Sx49802...
Page 73: ...Samba Plus Top Schema elettrico cassetti Trays wiring diagram...
Page 76: ......